background image

9A

9B

V

PU

SERR.

L       N

LAMP

230V

MOTORE 1

AP COM CH

MOTORE 2

AP COM CH

1

1

1

2

2

2

3

3

3

4

4

5

5

6 7 8 9 10

1

2

1

1

2

2

3 4 5 6 7 8 9 10 11

MOT.2

SERR.

+    - + V 

CN1

CN2

MOT.1

LAMP

+   -

BAT

+12V-

12/20V

S.P.

+

EN

EN

06. COMPONENTS TEST

24V MOTOR

110V/230V MOTOR

05. CONNECTION SCHEME

MOTOR WIRES 

|

 CONNECTIONS

Connections should be made as shown above, connecting the 6 motor wires to the appropriate 

inputs of the central and capacitor.

NOTE

: The white motor wires are connected directly to the capacitor wires!

24V MOTOR

Test A

 • Make the connections as indicated in the image. 

If the motor works, the problem is in the control board. If it does not operate, do the test B.

Test B

 • Loosen the 4 screws to remove the cover and access the internal connections.

Make the connections as indicated in the image.

If the motor works, the problem is on the diode(s) or on the micro(s). If it does not operate, 

replace with a new 24V engine and re-test to ensure that all is ok.

To detect which are the components with problems in a 24V JAG automatism installation, it is 

necessary to conduct tests with a direct connection to a external power supply (bateria 24V). 

In the scheme below is shown how it should be done this link.

NOTES:

• Once you connect the wires to a 24V battery, the motor must work for one direction. To test 

the reverse movement, change the position of the wires connected to the battery.

ТЕSТ A

ТЕSТ B

Yellow/Green

Brown 

Gray

Black

White

White

Wires color

Motor 1 wires

Motor 2 wires

Ground Wire

MOTOR-AP

MOTOR-COM

MOTOR-CH

Capacitor

Capacitor

Ground Wire

MOTOR-CH

MOTOR-COM

MOTOR-AP

Capacitor

Capacitor

•  

These connections correspond to an 

installation with an opening to the interior

. If the au-

tomation is installed with an opening towards the 

outside

 of the gate, you 

must swap the AP 

wire with the CH wire

 on the motor 1 and 2.

•  

If the 

motors work towards the opposite direction, swap AP with CH

.

Summary of Contents for JAG Series

Page 1: ...V4 1 REV 04 2018 JAG EN USER S AND INSTALLER S MANUAL...

Page 2: ...s marking on the product or literature indicates that the product andelectronicaccessories eg Charger USBcable electronicmaterial controls etc should not be disposed of as other household waste at the...

Page 3: ...product in an emergency and provide him the manual This device can be used by children 8 year old or older and persons whose physical sensory or mental capacities are reduced or by persons without ex...

Page 4: ...ic components in the kit Kit Package JAG specifications are as follow 01 02 03 JAG400 JAG600 Power Supply 230V 230Vac 50 60Hz 230Vac 50 60Hz 110V 110Vac 50 60Hz 110Vac 50 60Hz 24V 24Vdc 24Vdc Power 23...

Page 5: ...tical distance from the floor to the top of the front support Set dimension A this can be any size of your choice After you set dimension A subtract 20mm to find dimension B It is very important that...

Page 6: ...120 a 140 1295 1300 JAG 600 95 120 a 350 120 a 200 1695 1700 120 200 a 280 120 a 200 1695 1700 HORIZONTAL INSTALLATION DIMENSIONS EXTERIOR OPENING EXTERIOR INTERIOR Distance between the centers of the...

Page 7: ...be able to stretch retract arm easily see page 03B to get the correct position for supports Install the pins removed earlier on each side with a small amount of lubricant for less friction Unlock the...

Page 8: ...the gate to the open position 07 Loosen the screw shown in the image 24 so that it is possible to move the micro switch in the profile 08 Adjust the closure micro switch B until it makes click on the...

Page 9: ...tant to use mechanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will b...

Page 10: ...n the micro s If it does not operate replace with a new 24V engine and re test to ensure that all is ok To detect which are the components with problems in a 24V JAG automatism installation it is nece...

Page 11: ...or Motor Motor Motor Black Black Gray Gray Brown Brown COM COM Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply AUTOMATION AUTOMATION Ground Wire Ground Wire Ground Wire G...

Page 12: ...cloth remove the ex cess leaving a homogeneous layer of lubri cant over the arm Place a small amount of lubricant on the holes that contains support pins Check motor supports Make sure that supports r...

Page 13: ...board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagnos...