Operator must be installed with a small inclination , to prevent water infiltration through the
extension arm.
For this, the front support must be fixed to the gate with a height lower than the height of the
rear support. See example below:
Example:
• If the height of the rear bracket (dimension A)is set at 600 mm, then the height of the front
bracket (dimension B) will be 580 mm (600mm-20mm).
Dimension A
•
Vertical distance from the floor to the top of the rear support.
Dimension B
•
Vertical distance from the floor to the top of the front support.
• Set
dimension A
(this can be any size of your choice).
• After you set
dimension A
, subtract
20mm
to find
dimension B
.
It is very important that these dimensions are respected! Only this way can be assured the
correct functioning and durability of the operators!
It is also very important to have a levelled ground/terrain!
VERTICAL INSTALLATION DIMENSIONS
03. OPERATOR
TECHNICAL SPECIFICATIONS
LOCK/UNLOCK MOTOR
04. INSTALLATION
Place the unlocking key in the slot signed on
image 05 (motor installed on the left) or 06
(motor installed on the right).
Turn the key to lock or unlock the motor (07).
08
JAG 400 || 600
dimensions are the following:
04
1375mm
||
1775mm
975mm
||
1175mm
110mm