background image

4A

4B

06

A

A

B

B

05

07

08

04

EN

EN

A

?? 

mm

B

A - 

20mm

Operator must be installed with a small inclination , to prevent water infiltration through the 

extension arm.

For this, the front support must be fixed to the gate with a height lower than the height of the 

rear support. See example below:

Example:

 

• If the height of the rear bracket (dimension A)is set at 600 mm, then the height of the front 

bracket (dimension B) will be 580 mm (600mm-20mm).

Dimension A

 • 

Vertical distance from the floor to the top of the rear support.

Dimension B

 • 

Vertical distance from the floor to the top of the front support.

• Set 

dimension A

 (this can be any size of your choice).

• After you set 

dimension A

, subtract 

20mm

 to find 

dimension B

.

It is very important that these dimensions are respected! Only this way can be assured the 

correct functioning and durability of the operators!

It is also very important to have a levelled ground/terrain!

VERTICAL INSTALLATION DIMENSIONS

03. OPERATOR

TECHNICAL SPECIFICATIONS

LOCK/UNLOCK MOTOR

04. INSTALLATION

Place the unlocking key in the slot signed on 

image 05 (motor installed on the left) or 06 

(motor installed on the right). 

Turn the key to lock or unlock the motor (07).

08

JAG 400 || 600

 dimensions are the following:

04

1375mm

 || 

1775mm

975mm

 || 

1175mm

110mm

Summary of Contents for JAG Series

Page 1: ...V4 1 REV 04 2018 JAG EN USER S AND INSTALLER S MANUAL...

Page 2: ...s marking on the product or literature indicates that the product andelectronicaccessories eg Charger USBcable electronicmaterial controls etc should not be disposed of as other household waste at the...

Page 3: ...product in an emergency and provide him the manual This device can be used by children 8 year old or older and persons whose physical sensory or mental capacities are reduced or by persons without ex...

Page 4: ...ic components in the kit Kit Package JAG specifications are as follow 01 02 03 JAG400 JAG600 Power Supply 230V 230Vac 50 60Hz 230Vac 50 60Hz 110V 110Vac 50 60Hz 110Vac 50 60Hz 24V 24Vdc 24Vdc Power 23...

Page 5: ...tical distance from the floor to the top of the front support Set dimension A this can be any size of your choice After you set dimension A subtract 20mm to find dimension B It is very important that...

Page 6: ...120 a 140 1295 1300 JAG 600 95 120 a 350 120 a 200 1695 1700 120 200 a 280 120 a 200 1695 1700 HORIZONTAL INSTALLATION DIMENSIONS EXTERIOR OPENING EXTERIOR INTERIOR Distance between the centers of the...

Page 7: ...be able to stretch retract arm easily see page 03B to get the correct position for supports Install the pins removed earlier on each side with a small amount of lubricant for less friction Unlock the...

Page 8: ...the gate to the open position 07 Loosen the screw shown in the image 24 so that it is possible to move the micro switch in the profile 08 Adjust the closure micro switch B until it makes click on the...

Page 9: ...tant to use mechanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will b...

Page 10: ...n the micro s If it does not operate replace with a new 24V engine and re test to ensure that all is ok To detect which are the components with problems in a 24V JAG automatism installation it is nece...

Page 11: ...or Motor Motor Motor Black Black Gray Gray Brown Brown COM COM Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply AUTOMATION AUTOMATION Ground Wire Ground Wire Ground Wire G...

Page 12: ...cloth remove the ex cess leaving a homogeneous layer of lubri cant over the arm Place a small amount of lubricant on the holes that contains support pins Check motor supports Make sure that supports r...

Page 13: ...board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagnos...