EN
30
MESSAGES MEANING
--
Gate closed or switch-on after shutdown
OP
Gate opening
CL
Gate closing
SO
Gate stopped during opening
SC
Gate stopped during closure
F1
Photocell 1 tripped
F2
Photocell 2 tripped
HA
Gate stopped by external event
ALI
Re-alignment procedure
oP
Gate stopped without automatic reclosure
OPd
Gate in parcial opening mode
Pe
Gate in parcial opening position without automatic reclosure
-tC
Gate open with timed reclosure
Flashing dash counting in progress
Dash replaced by figures 0..9 countdown (last 10s)
-tP
Gate in parcial opening position with timed reclosure
Flashing dash counting in progress
Dash replaced by figures 0..9 countdown (last 10s)
L--
Learning started on limit switch (move the gate off the limit switch to continue the learning procedure) or learning
stopped due to trip of safety device or motor inversion.
LOP
Learning opening
LCL
Learning closure
4.7 - Display during normal operation
In “NORMAL OPERATING MODE”, i.e. when the system is powered up normally, the 3-figure LCD display shows the following status messages:
In addition, the dots between the figures illustrate the status of the limit switches, as described in greater detail below:
MESSAGES MEANING
-
.
-
Limit switch CLOSED (one dot between the two lines)
tC
.
Limit switch OPEN (a point to the right)
SO
No limit switch active (no dots present)
EVENT
DESCRIPTION
BUTTON TO MAIN CONTROL FLASHING
LIGHT AND LEDS CONTROL UNIT
opening
Gate opening
closure
Gate closing
automatic closure
Gate open with timed reclosure active
stop during closure
Gate stopped during closure
stop during opening
Gate stopped during opening
open
Gate completely open without automatic reclo
-
sure
closed
Gate completely closed
programmation
During the programming phase
2 quick f pause + 1 flash
obstacle M1
Motor 1 obstacle detected
4 quick f pause, 3 times
photo 1!
Photocell 1 tripped
2 quick f pause, 3 times
photo 2!
Photocell 2 tripped
2 quick f pause, 3 times
sensitive edge!
Sensitive edge tripped
5 quick f pause, 3 times
parcial opening
Parcial opening in progress
automatic parcial closure
Gate opening to parcial position with timed reclo
-
sure activated
realignment
Realignment after a manual release
phototest error
Phototest error detected
3 quick f pause, 3 times