EN
28
MOTOR CONNECTOR
Power supply connection terminal board
M +
Power supply motor
M -
Power supply motor
V +
DO NOT USE
ENC
DO NOT USE
NEG
DO NOT USE
POWER SUPPLY CONNECTOR
L
Power supply live 230 Vac (120 Vac) 50-60 Hz
N
Power supply neutral 230 Vac (120 Vac) 50-60 Hz
Earth
ATTENTION - Before making the connections, ensure that the control unit is not powered up.
4.6 - Electrical connections
NEG
PH-POW
STOP
STOP
PH 2
24 VAC
24 VAC
PH 1
OPEN
CLOSE
SBS
PAR
COM
PHOTOTEST
OPEN
PHOTOCELL 1
PHOTOCELL 2
CLOSE
PARCIAL
STEP BY STEP
COMMON
STOP/EDGE
NEGATIVE
24 VAC
24 VAC
POWER
SUPPLY
STOP
STOP
PH2
PH1
OPEN
CLOSE
PAR
SBS
PH2 PH1
UP
MENU
SBS
DOWN
(RADIO)
NEG
ENC
V +
M -
M +
BATTERY
LS 1
LS 2
KEY
COM
OUTPUT LED
INDICATOR
COM
FLASH
IND ELEC
LED
COMMON
FLASH
N
T1,6A
L
230Vac 50/60Hz
POWER
SUPPLY
SHIELD
ANT
SHIELD
ANT
COMMON
FLASH
PH1
RX
2
1
PH1
TX
DIP SWITCH
Set on “ON” to disable inputs STOP, PH1, PH2
Eliminates the need to bridge the terminal board inputs.
WARNING - With the dip switch ON, the
safety devices are disabled
ON
OFF
EXAMPLE: With only 1 photocell
connected set STOP and PH2 to ON
ON
OFF
DO NOT USE
DO NOT USE
DO NOT USE