21
•
WARNING:
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
•
CAUTION:
The gas pressure regulator provided with this appliance must be used.
This regulator is set for an outlet pressure of 2.7 kPa(ll” WC).
• This unit is not intended to be installed on recreational vehicles and/or boats.
• The gas supply must be turned off at the LP-Gas supply cylinder when this appliance is
not in use.
• The installation must conform with local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.l-1998 for US and with the CAN1- B149 for
Canada.
• To test for a gas leak, place soapy water around the regulator. If bubbles appear, there is
a gas leak.
• The hose assembly must be replaced prior to the appliance being put into operation if
there is evidence of excessive abrasion or wear, or if the hose is damaged. The
instructions shall state that the replacement hose assembly shall be that specified by the
manufacturer.
• The Mosquito Magnet® Liberty Plus is equipped with a hot surface ignition device.
Failure to follow starting procedure will result in the trap not starting.
• Installation and repair should be done by a qualified service person. The heater should
be inspected before use and at least annually by a qualified service person. More frequent
cleaning may be required as necessary. It is imperative that the control compartment,
burners, and circulating air passageways of the heater be kept clean.
• Adequate clearances of 50-6Ocm(20-24 in) around air openings into the combustion
chamber, clearances from combustible material, provisions for accessibility and for
combustion and ventilating air supply. Keep the Mosquito Magnet® Liberty Plus area
clear and free from combustible materials, gasoline, and other flammable vapours and
liquids. The appliance is not to be used in locations where flammable vapour or explosive
dust is likely to exist.
• Do not obstruct the flow of combustion and ventilation air.
• Keep the ventilation openings of the cylinder enclosure free and clear from debris.
• Clean the Mosquito Magnet® Liberty Plus with a water damp cloth, if necessary.