Customer Care
**Please have your serial number, date of purchase & model type available**
All of us at Woodstream
®
Corporation want you to get complete satisfaction from your Liberty Plus. Should you have any problems you
cannot resolve, simply call one of our trained Customer Care Representatives at
1-800-953-5737 or visit www.mosquitomagnet.com.
We will help you get up and running.
Unit won’t start
Red LED light flashing
at 7 second intervals
Unit won’t stay running
Low or No Catch
1. Propane tank may be empty.
2. If propane tank is new and has been newly filled
it must be purged.
3. There could be a loose connection.
4. Fuel line maybe blocked by propane contaminants.
1. ‘Possible Causes’ 1 & 3 above may apply.
2. Fuel line may be blocked by propane contaminants.
3. Regulator is not fully engaged.
1. Insects may not be out yet.
2. Trap placement issue.
3. Biting insect reproductive cycles have not yet
been broken.
4. Counterflow may be disrupted.
1. Weigh tank and check against “empty” weight
written on tank.
2. Bring tank to filling location. Air may be in
fuel line. Ask for tank to be purged.
Hint: If you have another propane powered device
operating on a standard, 20 lb propane tank, try
hooking that tank up to the Liberty Plus to verify
that the issue is with your tank.
3. Verify all connections. Make sure propane tank
valve is fully open.
4. See Quick Clear adapter instructions on page 13.
1. Go through above steps 1 & 3.
2. See Quick Clear adapter instructions on page 13.
3. See Tank Changing Tips on page 8.
1. Verify temperature is consistently over 50°F (10°C).
2. Follow steps in the “Trap Placement” section
of your owner’s manual or refer to your instructional
CD-ROM included with your Liberty Plus.
3. Keep trap in constant operation 24 hours/day,
7 days per week for at least 4-6 weeks to
reduce the mosquito population.
4. Air flow may be restricted. Call Customer Care
at:
1-800-953-5737.
LED Flashing alt RED/GREEN
at 7 second intervals
LED Flashing alt
RED/ORANGE
at 7 second intervals
High Temperature
Battery Voltage Low
1. Turn off trap and allow to cool for 1/2 hour.
Then restart. If code continues, call
Customer Care at:
1-800-953-5737.
1. Make sure you have charged the battery for
24 hours before starting trap for the first time out
of the box and the first time before each season.
2. Check all battery connections, make sure
they are fully inserted.
3. After several repeated unsuccessful attempts
to start your Mosquito Magnet
®
the battery
may need to be recharged.
Double flashing Red LED
at 7 second intervals
Thermister fault
1. Contact Customer Care at 1-800-953-5737
1. Contact Customer Care at 1-800-953-5737
LED light solid red
Electrical fault
Solutions
Possible Cause
Problem
Easy Quick-Clear Valve
Troubleshooting
Important: Extinguish all smoking materials prior
to use of Easy Quick-Clear Valve. Do not stand directly
behind the Quick Clear cartridge during operation.
Use of PROTECTIVE eyewear is recommended.
Quick Clear is recommended for regular maintenance to
remove built-up contaminants but is not required for
operation of your Liberty Plus.
Recommended for use at first tank change, and every
second tank change thereafter. Also recommended for use
before seasonal storage to avoid build up of contaminants
during the off-season. Instructions for “Easy Quick-Clear
Valve” Maintenance procedure shall be provided on a label
attached to appliance where easily visible by user.
The Easy Quick-Clear Valve is a gold, threaded knob located
on the back of your trap. It should be used with the adapter
included with your Liberty Plus, and a threaded Quick Clear
cartridge available on our website at: www.mosquitomagnet.com
or at your local Mosquito Magnet
®
Dealer.
1. Shut down your Liberty Plus. Let fan run until it stops.
(About 5 minutes).
2. Close the propane tank valve by turning to the “OFF”
position. (Turn the tank valve clockwise).
3. Remove the protective cap from Easy Quick-Clear
Valve on your trap.
4. Hand-screw the Quick Clear adapter on to Quick Clear
valve, until finger tight.
5. Hand-screw the Quick Clear cartridge into the Quick
Clear adapter clockwise until hand tight while holding
the adapter in place.
Important:
Do not over-tighten.
6. While holding the adapter in place
slowly
unscrew
Quick Clear cartridge up to
1/4 turn only
in counter
clockwise direction from the Quick Clear adapter only.
The strong flow of compressed air lasts approximately
45 seconds. Be sure to allow Quick Clear cartridge to
run out completely. (Hissing will stop when cylinder is
empty. Quick Clear cartridge will be cold to the touch)
7. Unscrew the Quick Clear cartridge to remove. Discard empty
Quick Clear cartridge after use, it is not reusable or refillable.
8. Unscrew the Quick Clear adapter to remove.
Use caution when removing Quick Clear adapter and
cartridge, as some compressed air may come out at this time.
Remember to keep the Quick Clear adapter for future use.
9. Replace Easy Quick-Clear Valve protective cap, and
proceed with normal start up of your Liberty Plus. If use
of Easy Quick-Clear Valve feature does not resolve
starting trouble, contact Customer Care
1-800-953-5737.
Unscrew the Quick Clear cartridge first, then unscrew Quick
Clear adapter and discard the spent Quick Clear cartridge.
Remember to keep the Quick Clear adapter for future use.
To start cleaning process, while holding Quick Clear
adapter in place, unscrew the Quick Clear cartridge
1/4 Turn Only
.
While holding the adapter in place, screw the Quick Clear
cartridge into Quick Clear adapter.
First hand-screw the Quick Clear adapter onto the valve.
Step 4
Step 5
Step 6
Step 7