12

Maintenance

11

Instructions

Starting Instructions

It is recommended that you read the entire manual
before starting the Liberty Plus trap.

1. Charge your Mosquito Magnet

®

Liberty Plus for 

24 hours at the beginning of each season.

2. Connect regulator to propane tank (see page 8).

3. Slowly open propane tank valve.

4. Push ON/OFF switch to ON position. 

LED light will turn solid orange indicating warm-up. 
After 15 to 25 min. trap LED light will turn solid green
indicating the trap is running at full capacity.

When Not In Use

If the unit is not in use, the gas must be turned off at the
supply cylinder. Storage of this unit indoors is permissible
only if the cylinder is disconnected and removed.
Cylinders must be stored outdoors, out of reach of
children and must not be stored in a building, garage or
any other enclosed area.

End of Season Storage

Push ON/OFF switch to OFF position to shut down the
Liberty Plus. The LED light will go out and the fan will
continue running until trap is cool. Close the propane tank
valve and disconnect regulator. Also, disconnect the
battery, but make sure not to remove battery from the trap.

Any open Mosquito Magnet

®

attractant should be

removed and discarded. See attractant label for
disposal instructions. The bug bag should also be
discarded prior to storing the Liberty Plus.

STORAGE:

Liberty Plus should be stored indoors in a

garage or shed in the off-season. Cover trumpet to
prohibit insects from nesting. Cover unit with trap cover
available at www.mosquitomagnet.com or with a tarp
and secure tightly at the bottom to keep out dust, spider
webs and other debris.

NOTE:

It is recommended that you use the Quick Clear
cartridge before seasonal storage to avoid build-up 
of contaminants during off-season (see page 13).

Shut Down

Maintenance 

• 21 Day Maintenance Cycle

- Refill propane. (Propane lasts approximately 21 days with 

24-hour/7-days operation.)

- Replace short-range attractant cartridge.

See Mosquito Magnet

®

attractant label for instructions.

- Empty or replace bug bag.

• Utilize the Quick Clear adapter at first tank change and every

second tank change thereafter.

• Periodically wipe down the outside of the Liberty Plus 

with a clean, water damp cloth.

• Charge your Mosquito Magnet Liberty Plus for 24 hours at the

beginning of each season.

Propane Tank Changing Tips

When attaching the regulator knob to a tank after a tank change,
be sure to fully tighten the regulator knob onto the tank. No need
to use tools, but do turn the knob as far as possible by hand.
When this is done, loosen the knob 1/4 turn, then re-tighten 
to maximize seal. 

The purpose for this is to fully engage the regulator onto the tank. If
the regulator is not fully engaged, the flow of gas may be restricted
to the point where the trap will show a gas empty code. If this
occurs, press the off button, close the tank valve, and remove the
regulator from the tank. Re-attach the regulator and try again.

**READ MANUAL BEFORE STARTING**

Possible Cause

Maintenance Schedule

Note: Bug bags should be replaced when half full. You can find all your accessory needs 

at www.mosquitomagnet.com or at your local Mosquito Magnet Dealer or Service Center.

Example

Season 1

Season 2

Season 3

Season 4

Purchase Date
Warranty Submission
Start Up Date

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

Propane & Attractant Change
Quick Clear Cartridge

4/1
4/1
4/1

4/21
4/21

5/11

5/31
5/31

6/20

7/10
7/10

7/30

8/19
8/19

9/8

9/28
9/28

Please visit www.mosquitomagnet.com to find 

a local service provider for your spring tune-up.

ON/OFF Switch

For Best Results (unit must run for 24 hours/day)

Your trap will begin capturing immediately with
significant reduction in the mosquito population in 
7-10 days

. Allow 4 – 6 weeks to significantly reduce the

mosquito population in your yard.

• Never spray insecticide in or around trap.
• Trap can be left running in the rain, but do not place trap

directly above a water source (sprinklers, hose, etc.).

• If using lime or fertilizer compounds, be sure to shut down

the Liberty Plus first to prevent dust or fine mist from being
drawn into trap and clogging bug bag.

Warning:

Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage. Read the
installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.

Caution:

The gas pressure regulator provided with this appliance

must be used. This regulator is set for an outlet pressure 11.0 in.
water column.

The gas supply must be turned off at the LP-Gas supply cylinder
when this appliance is not in use.

Summary of Contents for Liberty Pluse

Page 1: ...For Outdoor Use Only 1440 604 Rev E...

Page 2: ...logy Woodstream Corporation 69 North Locust Street Lititz PA 17543 1 800 953 5737 www mosquitomagnet com Patents USA Nos 6 145 243 6 286 249 6 817 140 6 840 005 6 848 466 7 243 457 and 7 281 351 Canad...

Page 3: ...egulatorprovidedwiththis appliance must be used This regulator is set for an outlet pressure of 11 0 in Water Column The minimum inlet gas supply pressure is 11 0 in Water Column from regulator This u...

Page 4: ...arts Included Self Contained Liberty Plus Power Head 1 Trumpet 1 Support Pole 1 Base Support 1 Regulator Hose 1 Bug Bag Mosquito Magnet Octenol Biting Insect Attractant EPA Reg No 72563 1 Short Range...

Page 5: ...front of you within 5 6 feet of ground cover i e bushes flowerbeds tree line marshbed Ensure that trap is not directlyagainstanyblockadessuchasbuildings fences etc 4 It is recommended that the trap b...

Page 6: ...preferably by mouth to mouth if possible Call a poison control center or doctor for further treatment advice Have the product container or label with you when calling a poison control center or docto...

Page 7: ...tank after a tank change be sure to fully tighten the regulator knob onto the tank No need to use tools but do turn the knob as far as possible by hand When this is done loosen the knob 1 4 turn then...

Page 8: ...Possible Cause Problem Easy Quick Clear Valve Troubleshooting Important Extinguish all smoking materials prior to use of Easy Quick Clear Valve Do not stand directly behind the Quick Clear cartridge d...

Page 9: ...e a defect Woodstream Corporation will issue a Return Goods Authorization RGA number The defective unit or parts must be returned for warranty inspection using the RGA number when applicable as identi...

Page 10: ...Manual de operaci n...

Page 11: ...ada Counterflow Technology Woodstream Corporation 69 North Locust Street Lititz PA 17543 1 800 953 5737 www mosquitomagnet com Patentes EE UU No 6 145 243 6 286 249 6 817 140 6 840 005 6 848 466 7 243...

Page 12: ...eartefacto Estereguladorest fijado paraunapresi ndesalidade28cmdecolumnadeagua Lapresi nm nimadelsuministrodegasdeentradaes para28cmdecolumnadeaguadelregulador Esta unidad no est dise ada para instala...

Page 13: ...cluidas Artefacto Liberty Plus aut nomo Cabezal de alimentaci n el ctrica 1 Trompeta 1 Poste de soporte 1 Soporte de la base 1 Manguera del regulador 1 Bolsa para insectos Cebo atrayente para insectos...

Page 14: ...m es decir arbustos cantero de flores l neas de rboles pantano Aseg rese que la trampa no est ubicada contra objetos de bloqueo como edificios cercas etc 4 Se recomienda ubicar la trampa en la sombra...

Page 15: ...n Lleve a la persona al aire fresco Si la persona no est respirando llame al 911 o a una ambulancia luego aplique respiraci n artificial preferiblemente boca a boca si es posible Llame al centro de c...

Page 16: ...justar completamente la perilla del regulador al tanque No necesita utilizar herramientas pero aseg rese de girar la perilla todo lo posible a mano Despu s de hacer esto afloje la perilla 1 4 de vuelt...

Page 17: ...953 5737 Comun quese con el Servicio de Atenci n al Cliente llamando al 1 800 953 5737 Luz LED roja encendida Fallo el ctrico Soluciones Causa probable Problema V lvula Easy Quick Clear Soluci n de p...

Page 18: ...entregar un n mero de Autorizaci n de Devoluci n de Producto RGA por las siglas en ingl s de Return Goods Authorization La unidad o partes defectuosas deben devolverse para la inspecci n de garant a u...

Reviews: