4. Description
24
Type B - DGUV version
1
2
4
3
5
6
7
8
9
16
10
11
12
13
17
14
11
15
D5260340
1 -
Control panel power switch (ON-OFF)
2 -
DPF (Diesel Particulate Filter) manual regeneration button
3 -
DPF (Diesel Particulate Filter) regeneration inhibition button
4 -
Command and control unit
5 -
Protection fuses
6 -
Buzzer
7 -
Insulation monitor
8 -
Main machine switch
9 -
Residual current circuit breaker (RCCB) (4P 300mA Type B) for three-phase 63A 400V sockets
10 - Residual current circuit breaker with overcurrent protection (RCBO) (4P 32A - 30mA Type B) for three-
phase 32A 400V sockets
11 - 16A 230V 2P+T CEE IP54 socket (No. 2)
12 - 63A 400V 3P+T CEE IP67 socket
13 - 32A 400V 3P+T CEE IP67 socket
14 - 16A 400V 3P+T CEE IP67 socket
15 - Residual current circuit breaker with overcurrent protection (RCBO) (2P 16A - 30mA Type B) for
SCHUKO 16A 230V sockets (2)
16 - Residual current circuit breaker with overcurrent protection (RCBO) (4P 16A - 30mA Type B) for three-
phase 16A 400V sockets
17 - Equipotential ground terminal