Powered Setup Procedure.
The "Powered Set-Up Procedure" does require connection to the Mains Power Supply so
please ensure that all Covers & Guards are replaced & secure before proceeding. Adjustments
to the Control System & Circuit Boards should only be carried out by fully trained & qualified
personnel.
An Engineering Calibration Plug (Part Number 90-046) will be required to enable access to the
Advanced Tools Section of the Display Screen and an adequate supply of DigiFold Test Sheets
(Part Number 170-004-01) should be made available for many of the set-up procedures.
The Control System comprises many components, including Power Supplies & Circuit Boards,
some of which require some degree of setting or adjustment. This section describes the
procedures required to carry out this work.
Connect the machine to a suitable Mains Supply & Power Up by releasing the Stop
Switch on the Front Panel. The Display Panel will initially show the ‘ Are you trained
screen. It's worth making a note of the Software revision to ensure it's the
latest available for the machine build level, check this by going to the tools menu
and operating the information button.
There is one Dual Stepper Drive Board and three single Stepper Drive Boards,
located on the lower section of the Electronics Panel. These boards are fitted with
and
. These
switches must be set in accordance with the correct Circuit Diagram issue for the
Serial Number of the machine being set up. (See Digifold Wiring Diagrams)
If the
is not visible, adjust the Brightness & Contrast and channel on the
rear of the touchscreen. See ‘Calibration of touch screen’ on Page 22.
There are four Switched Mode
located on the outside of the Layside
Frame Plate - three 48volt supplies and one 24volt supply. The voltage of each supply
should be set to the appropriate level as shown on the Circuit Diagram. The controls for
these settings are located on the top left hand corner of each supply and may be
adjusted using a small insulated electrical screwdriver. It will be necessary to operate
the System Switch on the Front Panel & use a suitable Volt Meter to do this.
Do not use damaged Test Sheets.
11.
Control System Set-Up:-
11.1.
11.2.
11.3.
11.4.
Power Selection Slide Switches
Step Selection Slide Switches
Display
Power Supplies
IMPORTANT.
CREASING / FOLDING
Summary of Contents for Digifold Pro CB
Page 7: ...Page 7 SYSTEM BLANK PAGE Digifold Pro ...
Page 13: ...Page 13 SYSTEM Digifold Pro ...
Page 17: ...Page 17 SYSTEM BLANK PAGE Digifold Pro ...
Page 21: ...Page 21 SYSTEM Layedge Side Operator Side Digifold Pro ...
Page 37: ...SYSTEM Page 37 BLANK PAGE Digifold Pro ...
Page 39: ...Page 39 SYSTEM Digifold Pro ...
Page 53: ...Page 53 BLANK PAGE Digifold Pro SYSTEM ...
Page 55: ...Page 55 Digifold Pro SYSTEM ...
Page 61: ...Page 61 Digifold Pro SYSTEM ...
Page 73: ...Page 73 Digifold Pro SYSTEM ...
Page 79: ...Page 79 Digifold Pro SYSTEM ...
Page 88: ...Page 88 CREASING FOLDING Section N BL YEL ...
Page 92: ...Page 92 CREASING FOLDING Mod No Rev Mod Description Date Mod By REVISION HISTORY ...