SECTION H
Changing Sensors on the Folder unit
Clip Sensors.
There are two sets of Clip sensors and both are located just after a set of fold rollers.
They act as machine cutouts in cases of malfunction within the folding cycle.
1.
The sensor head can be changed as follows.-
2.
Unscrew the soc set dog point screw from the housing to allow the post to rotate.
Clip 1 & 2 Sensor Assembly :-
3.
Unscrew the soc set screw from the post that retains the leg of the sensor.
4.
Rotate the post through 180 degrees to gain access to the other leg and unscrew this
screw.
5.
Replace the sensor with a new unit and retighten the leg screws.
Note.-
All sensors can be tested for operation without removing the covers by
initiating the ‘Sensor Test’ via the Tools Menu!
(See page 65)