background image

www.miinet.com

Moore Industries-International, Inc.

- 6 -       

User’s Manual

235-781-00D

June 2019

T2X RTD Temperature Transmitter

T2X

Installing the Software

Before the transmitter can be configured, the T2X PC Configuration Program must be installed on a PC with 

the following: 

•   Microsoft Windows based PC;

•   16Mb free RAM; 

•   20MB free disk space on hard drive

•   Microsoft Windows® 7, 10

Note:

 One (1) available serial communications (COM 1, 2, 3 or 4) or USB port

Configuring the T2X

The T2X is configured using an easy-to-use PC Configuration Program; there are no internal or external controls 

to adjust or settings to change. All operating parameters are set using the PC program, then downloaded to 

the nonvolatile memory of the T2X in the form of a configuration file
Pages 7-8 of the manual contains all of the instructions for configuring the T2X. Use Figure 2 to find the portion 

of the screen that you have a question about. The number by that area will correspond with the instructions.

Table 1.  Equipment needed for setting up the T2X.

        

 

        Device 

        

 

 

 

 

        

Input 

             

Potentiometer, Simulator, or Decade 

Resistance Box 

Power Supply
Precision  Load Resistor (optional)

Multimeter

RTD Temperature vs. Resistance Tables
Personal Computer
Moore Industries’ T2X Configuration Program

Moore Industries’ Communication Cable

Accurate to ±0.05% of unit span

8-42Vdc, ±10%
2500, ±0.025 %
Accurate to ±0.025%, e.g. Fluke Model 87

Successfully installed on the hard disk of the 

specified PC

See “Installing Software”

ITS68 and ITS90, or equivalent

Fuse Protected, Non-Isolated USB 

 

Communication Cable (required by ATEX for 

products installed in Intrinsically-Safe areas) 

(PN 804-030-26)

Summary of Contents for TEMPTATION 2000 T2X

Page 1: ...e m a n d M o o r e R e l i a b i l i t y All product names are registered trademarks of their respective companies User s Manual T2X Temptation 2000 T2X RTD Temperature Transmitter No 235 781 00D Jun...

Page 2: ...the original sale www miinet com Demand Moore Reliability Locations World Headquarters Europe Australia 16650 Schoenborn Street North Hills California 91343 6196 U S A Tel 818 894 7111 Fax 818 891 28...

Page 3: ...re or condition that could injure the operator Qualified Personnel The Moore Industries product systems described in this manual may be operated only by personnel qualified for the specific task in ac...

Page 4: ...ng the T2X 6 Managing Configuration Files 7 Specifications 9 Accessories 9 Ordering Information 10 Installing and Connecting the T2X 11 Physical Instructions for Installing an Encapsulated Hockey Puck...

Page 5: ...e necessary equipment as listed in Table 1 installing the T2X PC Configuration Program onto your computer then connecting the T2X as shown in Figure 1 It is necessary to connect the T2X to the PC befo...

Page 6: ...T2X in the form of a configuration file Pages 7 8 of the manual contains all of the instructions for configuring the T2X Use Figure 2 to find the portion of the screen that you have a question about...

Page 7: ...o be saved and click Save Answer Yes to the dialogue box that pops up to finish saving the file Retrieving a Configuration File from Disk To retrieve a file click on the File button Use the display on...

Page 8: ...le its 4 20mA output to offset the performance or calibration of other instruments in the process loop To scale the output enter the desired Output Zero value in the Zero Scale Output box or use the s...

Page 9: ...ohms Recommended 35 ohms per wire for three wire inputs 5 ohms per wire for 10 ohm Cu inputs Damping 0 5 seconds user selectable Ambient Tem perature Operating Storage Range 40 C to 85 C 40 F to 185 F...

Page 10: ...ter cover LH2NS Explosion proof connection head with two entry ports inch NPT cable and process black metal cover LH2MS Explosion proof connection head with two entry ports M20 cable and inch NPT proc...

Page 11: ...that best suits your application 2 WIRE RTD or DECADE RESISTANCE BOX PS 2 3 4 1 PS POWER SOURCE 8 42Vdc CURRENT DRIVEN INSTRUMENT 3 WIRE RTD OR DECADE RESISTANCE BOX 4 WIRE RTD OR DECADE RESISTANCE BO...

Page 12: ...ocess Instrumentation Industry For 2 wire transmitters certified and intended to be operated as either Intrinsically Safe Non Incendive Class I Div 2 or Type N the power parameters are clearly stated...

Page 13: ...ng the cap clockwise Secure lock the cap by rotating the locking screw counterclockwise 4 Connect a ground wire between the ground screw on the LH2 enclosure to an appropriate earth ground Figure 4 In...

Page 14: ...to the receiving device see Note below Note Some of Moore Industries instruments can be classified as receivers IPT2 IPX2 etc and some can be classified as transmitters TRX TRY etc while some are both...

Page 15: ...ature Transmitter T2X This secti Locations Maximum 300uA an on contains im s m operating pa d 240uW mportant info arameters of t rmation regar the COM po rding installat ort for use in N tion of the T...

Page 16: ...D T6 Ta 60 C The T2X shall be installed in an enclosure meeting the requirements of ANSI ISA S82 02 01 or other applicable ordinary location standards No connections shall be made to the communicatio...

Page 17: ...Parameters can be found in Control Drawing 100 100 38 Non Incendive Applications Class I Division 2 Groups A D T6 Ta 60 C The model T2X is of open type unit Certified as a component for use only in o...

Page 18: ...www miinet com Moore Industries International Inc 18 User s Manual 235 781 00D June 2019 T2X RTD Temperature Transmitter T2X...

Page 19: ...No modifications are permitted without the notification and approval of the Q A Certification Engineer related dwgs or the Certifying Agency schedule dwgs 2 250 MODEL SERIAL TAG 1866A 2 S Class II II...

Page 20: ...This is a controlled Related or Schedule drawing No modifications are permitted without the notification and approval of the Q A Certification Engineer related dwgs or the Certifying Agency schedule...

Page 21: ...NOTICE RE PROPRIETARY INFORMATION This drawing and the information contained herein are the proprietary property of Moore Industries International Inc MIi and should not be reproduced or disclosed to...

Page 22: ...l or workmanship This policy extends to the original Buyer only and not to Buyer s customers or the users of Buyer s products unless Buyer is an engineering contractor in which case the policy shall e...

Reviews: