www.miinet.com
Moore Industries-International, Inc.
- 6 -
User’s Manual
235-781-00D
June 2019
T2X RTD Temperature Transmitter
T2X
Installing the Software
Before the transmitter can be configured, the T2X PC Configuration Program must be installed on a PC with
the following:
• Microsoft Windows based PC;
• 16Mb free RAM;
• 20MB free disk space on hard drive
• Microsoft Windows® 7, 10
Note:
One (1) available serial communications (COM 1, 2, 3 or 4) or USB port
Configuring the T2X
The T2X is configured using an easy-to-use PC Configuration Program; there are no internal or external controls
to adjust or settings to change. All operating parameters are set using the PC program, then downloaded to
the nonvolatile memory of the T2X in the form of a configuration file
Pages 7-8 of the manual contains all of the instructions for configuring the T2X. Use Figure 2 to find the portion
of the screen that you have a question about. The number by that area will correspond with the instructions.
Table 1. Equipment needed for setting up the T2X.
Device
Input
Potentiometer, Simulator, or Decade
Resistance Box
Power Supply
Precision Load Resistor (optional)
Multimeter
RTD Temperature vs. Resistance Tables
Personal Computer
Moore Industries’ T2X Configuration Program
Moore Industries’ Communication Cable
Accurate to ±0.05% of unit span
8-42Vdc, ±10%
2500, ±0.025 %
Accurate to ±0.025%, e.g. Fluke Model 87
Successfully installed on the hard disk of the
specified PC
See “Installing Software”
ITS68 and ITS90, or equivalent
Fuse Protected, Non-Isolated USB
Communication Cable (required by ATEX for
products installed in Intrinsically-Safe areas)
(PN 804-030-26)