T2X

Specifications

Input Accuracy:

   

Platinum RTD, 

 

±0.2°C (±0.36°F) 

 

Nickel RTD, 

 

±0.16°C (±0.29°F)

 

Copper RTD, 

 

±1.2°C (±2.16°F)

 

Ohms, ±0.4Ω

 

Output Accuracy:  

 

±0.05% of span 

NOTE:  

Overall accuracy is 

determined by combining 

input and output accuracy.  

It includes the combined  

effects of linearity, 

 

hysteresis, repeatability, 

and adjustment resolution.  

It does not include ambient 

temperature effect.  

 

Stability (max. span):

   

1 year = ±0.12%  

3 years = ±0.21% 

5 years = ±0.27%  

Measurement Cycle:   

Output updates at least 8 

times per second

 

Output Response Time

:  

256msec typical, 300msec 

maximum, for the output to 

change from 10% to 90% 

for an input step change of 

0% to 100% 

Ripple:

  10mV peak-to-

peak measured across a 

250ohm load resistor at 

frequencies up to 120Hz 

Over-Voltage Protection

:  

Input, 4Vdc peak, max.; 

Output, 48Vdc, max.

 

Digital Input Filter

:   

User-selectable, 50/60Hz

 

Power Supply and Load 

Effects:

  Negligible within 

specified power limits

 

Load Capability:

 

670 ohms @ 24V 

 

 = (Supply Voltage - 8V) 

                0.024A 

 

Burnout Protection:

  

User-programmable, 

 

Upscale to 24mA;

 

Downscale to 3.3mA 

Output Current Limiting

:  

25mA maximum

 

RTD & Ohms Excitation:

  

250µA, ±10%

 

RTD Lead Wire  

Resistance Maximum:

  

RTD resi 2 times 

the lead wire resistance 

must be less than 2000 

ohms; Recommended <35 

ohms per wire for three 

wire inputs; <5 ohms per 

wire for 10 ohm Cu inputs

 

Damping

:  0-5 seconds 

(user selectable)

 

Ambient Tem-

perature

Operating & Storage Range:

   

-40°C to +85°C 

 

(-40°F to +185°F)

 

Relative Humidity:

  

0-95%, non-condensing

 

Ambient Temperature Effect:

  

±0.03% of span/°C

 

RFI/EMI Immunity:

   

20V/M@20-1000MHz,when tested 

according to SAMA standard 33.1. 

(10V/m@80-1000MHz,

 

1kHz AM, when tested according to 

IEC 1000-4-3-1995)

 

Noise Rejection

:   

Common mode: 

 

100dB @ 50/60Hz; 

 

Normal Mode:  70dB typical at 

200mV peak-to-peak @ 50/60Hz

All settings are made using  

Moore Industries’ Intelligent PC 

Configuration Software, and then 

stored in non-volatile memory

HPP:  101 g (3.6 oz)

 

HPP in LH1:  428 g (15.1 oz)

 

HPP in LH2:  428 g (15.1 oz)

 

HPP in CH6: 173 g (6.1 oz)

 

Set Up

Weight

Performance 

(continued)

Performance 

Don’t See What You Need?

Accessories

Each T2X order comes with one copy of our 

 

Intelligent PC Configuration Software (Windows

®

 

compatible). To order additional software or cables:

750-75E05-01

Intelligent PC Configuration Software

803-039-26

Isolated Serial Configuration Cable 

(9-pin Serial Port)
Non-Isolated Serial Configuration Cable

(9-pin Serial Port)

803-040-26

Part Number

Part

Fuse Protected, Non-Isolated USB 

 

Communication Cable (required by ATEX for 

products installed in Intrinsically-Safe areas)

804-030-26

We offer a wide range of temperature assembly choices - 

 

this data sheet provides just a few examples. Whatever your 

 

temperature assembly needs are, our temperature interface 

 

solution experts are ready to help!

 

Summary of Contents for TEMPTATION 2000 T2X

Page 1: ...e m a n d M o o r e R e l i a b i l i t y All product names are registered trademarks of their respective companies User s Manual T2X Temptation 2000 T2X RTD Temperature Transmitter No 235 781 00D Jun...

Page 2: ...the original sale www miinet com Demand Moore Reliability Locations World Headquarters Europe Australia 16650 Schoenborn Street North Hills California 91343 6196 U S A Tel 818 894 7111 Fax 818 891 28...

Page 3: ...re or condition that could injure the operator Qualified Personnel The Moore Industries product systems described in this manual may be operated only by personnel qualified for the specific task in ac...

Page 4: ...ng the T2X 6 Managing Configuration Files 7 Specifications 9 Accessories 9 Ordering Information 10 Installing and Connecting the T2X 11 Physical Instructions for Installing an Encapsulated Hockey Puck...

Page 5: ...e necessary equipment as listed in Table 1 installing the T2X PC Configuration Program onto your computer then connecting the T2X as shown in Figure 1 It is necessary to connect the T2X to the PC befo...

Page 6: ...T2X in the form of a configuration file Pages 7 8 of the manual contains all of the instructions for configuring the T2X Use Figure 2 to find the portion of the screen that you have a question about...

Page 7: ...o be saved and click Save Answer Yes to the dialogue box that pops up to finish saving the file Retrieving a Configuration File from Disk To retrieve a file click on the File button Use the display on...

Page 8: ...le its 4 20mA output to offset the performance or calibration of other instruments in the process loop To scale the output enter the desired Output Zero value in the Zero Scale Output box or use the s...

Page 9: ...ohms Recommended 35 ohms per wire for three wire inputs 5 ohms per wire for 10 ohm Cu inputs Damping 0 5 seconds user selectable Ambient Tem perature Operating Storage Range 40 C to 85 C 40 F to 185 F...

Page 10: ...ter cover LH2NS Explosion proof connection head with two entry ports inch NPT cable and process black metal cover LH2MS Explosion proof connection head with two entry ports M20 cable and inch NPT proc...

Page 11: ...that best suits your application 2 WIRE RTD or DECADE RESISTANCE BOX PS 2 3 4 1 PS POWER SOURCE 8 42Vdc CURRENT DRIVEN INSTRUMENT 3 WIRE RTD OR DECADE RESISTANCE BOX 4 WIRE RTD OR DECADE RESISTANCE BO...

Page 12: ...ocess Instrumentation Industry For 2 wire transmitters certified and intended to be operated as either Intrinsically Safe Non Incendive Class I Div 2 or Type N the power parameters are clearly stated...

Page 13: ...ng the cap clockwise Secure lock the cap by rotating the locking screw counterclockwise 4 Connect a ground wire between the ground screw on the LH2 enclosure to an appropriate earth ground Figure 4 In...

Page 14: ...to the receiving device see Note below Note Some of Moore Industries instruments can be classified as receivers IPT2 IPX2 etc and some can be classified as transmitters TRX TRY etc while some are both...

Page 15: ...ature Transmitter T2X This secti Locations Maximum 300uA an on contains im s m operating pa d 240uW mportant info arameters of t rmation regar the COM po rding installat ort for use in N tion of the T...

Page 16: ...D T6 Ta 60 C The T2X shall be installed in an enclosure meeting the requirements of ANSI ISA S82 02 01 or other applicable ordinary location standards No connections shall be made to the communicatio...

Page 17: ...Parameters can be found in Control Drawing 100 100 38 Non Incendive Applications Class I Division 2 Groups A D T6 Ta 60 C The model T2X is of open type unit Certified as a component for use only in o...

Page 18: ...www miinet com Moore Industries International Inc 18 User s Manual 235 781 00D June 2019 T2X RTD Temperature Transmitter T2X...

Page 19: ...No modifications are permitted without the notification and approval of the Q A Certification Engineer related dwgs or the Certifying Agency schedule dwgs 2 250 MODEL SERIAL TAG 1866A 2 S Class II II...

Page 20: ...This is a controlled Related or Schedule drawing No modifications are permitted without the notification and approval of the Q A Certification Engineer related dwgs or the Certifying Agency schedule...

Page 21: ...NOTICE RE PROPRIETARY INFORMATION This drawing and the information contained herein are the proprietary property of Moore Industries International Inc MIi and should not be reproduced or disclosed to...

Page 22: ...l or workmanship This policy extends to the original Buyer only and not to Buyer s customers or the users of Buyer s products unless Buyer is an engineering contractor in which case the policy shall e...

Reviews: