18
Installation
XG0225 - 170223
Figure 8.b
Control Box / Power Vent Wire Routing Diagram
Figure 8.
(Control Panel Overview)
Figure 8.c
(Wall Switch Wire connection)
Section 4: Wiring
Ensure the wires are properly isolated from metal parts or control
system will be damaged
CAUTION
Heat Sensor /
Conmustion Switch
Control
Box
Horizontal
Power Vent
Termination
Vertical
Power Vent
Termination
Power cable Installation
required for either Horizontal
or Vertical Termination Vent
115Vac 60 Hz
supply from
Distribution Panel
Wall Switch
Power
Vent
20 foot control
cable to fireplace
(standard)
Left-side View
Right-side View
20 foot control cable to
replace (standard)
Horizontal
Power Vent
Termination
Control
Box
Power
Vent
Power cable Installation
required for either Horizontal
or Vertical Termination Vent
Wall Switch
115Vac 60 Hz
supply from
Distribution Panel
Vertical
Power Vent
Termination
Power Vent
Speed Control
Post Purge
Timer (3 min.)
Prepurge
Timer (1 min.)
Power Vent
Connector
Power Vent
Fuse (5A)
LED Power
Indicator
Control Panel
Fuse (5A)
Installing the Fireplace Control Box
Install the Fireplace Control Box in an accessible location. The location should
be where maintenance, adjustments and service may be made easily.
Installing the Wall Switch
The unit may be connected to a wall switch. The system operates on
a 24V AC. DO NOT connect this circuit to an external power source
LED
INDICATOR
115V
OUTLET
CONTROL
CABLE
POWER
VENT
HARNESS
WALL
SWITCH
115V
POWER
SUPPLY
FUSE