32
Operation
XG0225 - 170223
Section 10: Cleaning and Maintenance
General
•
Have the fireplace and installation inspected yearly. The inspection
must include, but is not limited to, the following:
• A visual check of the entire vent system and termination, where
accessible.
•
An inspection of the explosion relief flappers and the door
gaskets to ensure a proper seal.
• An inspection of the burner, vent run, and primary air openings.
•
An inspection of the gas valve, gas components, and pilot flame.
For your convenience a 1/8" manifold pressure tap is supplied
on the gas valve for a test gauge connection.
• Inspection of all optional equipment; fans, thermostats, remote
control lights, etc.
• For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
• For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
•
Always keep the fireplace area clear and free of combustible materials,
as well as gasoline and other flammable vapors and liquids.
• Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
• Inspection of glass doors and screen for damage and proper
installation.
Procedure for Checking Calibration of
Flue Gas Switch
1. Disconnect power vent harness from the plug in the control box.
2. Turn wall switch 'ON'.
3.
Monitor flue gas switch LED for 2 minutes and ensure LED does
not come on or the glow plug will not light during this period.
4.
Reconnect power vent harness to plug in the control box.
Cleaning
When the fireplace is first activated, there may be some smoke and a
visible film may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
•
Glass must be cleaned periodically to remove any film (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door. Handle the door
carefully, and clean it with non-abrasive, non-ammonia based
glass cleaners. One of the most effective products is Kel-Kem.
• During the initial firing, Silicone seals will "off gas", leaving a
visual deposit of a white substance on combustion chamber
walls. This can easily be removed using normal household
products.
• Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
Do not use ammonia or abrasive cleaners on the glass, they will
permanently etch the surface. Use an approved gas fireplace cleaner
such as Kel-Kem or White off.
NOTICE
Annual inspection list for determining safe operation of
a direct vent decorative gas appliance
1)
Inspect and operate the pressure relief mechanism to verify relief mechanisms are free
from obstruction to operate.
2)
Clean glass window with a suitable fireplace glass cleaner. Abrasive cleaners must not
be used. Be careful not to scratch the glass when cleaning.
3}
inspect the operation of the flame safety system Pilot or Flame rectification device.
4)
Inspect and ensure the lighting of the main burner occurs within 4 seconds of the
main gas valve opening. Visual inspection should match that outlined in the appliance
instruction manual. Inspect primary air openings for blockage.
5)
Inspect condition of vent and vent terminal for sooting or obstruction and correct if
present.
6)
Vacuum and clean any debris in the firebox that is not supposed to be there.
7)
Test and measure the flame failure response time of the flame safety system. It must
de-energize the safety shutoff in no more than 30 seconds.
8)
Check all accessible gas-carrying tubes, connections, pipes and other components for
leaks.
Bk
R
W
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Figure 14.
Gas valve
Summary of Contents for R Series