12
Installation
XG0225 - 170223
Figure 4.
Flue cover and collar removal, Top Vented fireplace.
Figure 4.b
Flue cover and collar installation, Rear Vented fireplace
R320 and R420 units have 5" and 8" venting and are converted to rear
venting in the same instructions as the 5" and 10"
NOTICE
Under no circumstances can Montigo flex venting be cut to
accommodate an installation. Use an alternative length to complete
your vent run.
NOTICE
Section 3: Venting
Montigo supplies a variety of power venting options. The location of
the power vent should be selected and laid out to provide the most
efficient possible run to an external wall or through the roof.
Notes For Planning Venting:
•
R-Series fireplaces are Power Vent Designated.
• Venting originates from the top or rear of the unit.
• Venting can terminate through the roof or exterior wall.
• For a detailed diagram of allowed termination locations, see
Appendix A.
• Once the termination location has been established refer to the
appropriate section for installation details.
•
All fireplaces are shipped Top Vent from the factory.
•
Follow the chart on page 14 or page 15 for maximum ventrun and
maximum elbows.
Section 3-1: Converting to Rear Vent
R-Series units are shipped for Top Vent installations. Follow the
instructions to convert unit for Rear Vent installation:
Section 3-1-1: Converting the Flue
1.
Remove the Rear flue cover with gasket on the flue outlet, as shown
in Figure 4. ENSURE YOU DO NOT DAMAGE THE FIBRE GASKETS.
2.
Remove the Top flue collar on the flue outlet, as shown in Figure
4. ENSURE YOU DO NOT DAMAGE THE FIBRE GASKETS.
3.
Install the removed Rear flue cover to the Top Vent outlet. Fasten
the cover with included hardware, as shown in Figure 4b.
Flue Cover Plate
(with gasket)
Iner
Flue Collar
(with gasket)
Inner Flue Collar
(with gasket)
Flue Cover Plate
(with gasket)
Flue Cover Plate
(with gasket)
Outer Flue
Collar (with
gasket)
Outer Flue
Collar
(with gasket)
Flue
Cover Plate
(with gasket)
4.
Install the collars to the rear vent outlet using the included
hardware, as shown in Figure 4.b
5. Proceed to Section 3-1-2: Converting Pressure Sensing Tube
and Air Baffle.