Page 15
XG0816 - 150204.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Figure 14a�
HP38PF*
Rear Vent
Venting Graph for
wall mounted
terminations.
Figure 14�
H38PF* or HL38PF* Rear Vent
Venting Graph for
wall mounted
terminations.
Notes Wall Mounted Terminations:
REAR VENT
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs
must
fall within the limits set by the venting graphs,
see
Figure 14 or 14a
.
Fireplace must be converted to Rear Vent configuration prior to
running vent, see
Figure 8 and 8a
.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the fireplace flue collar to
the wall flange of the termination. Plot on the Venting Graph
Figure 14
or 14a
with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 138", this would be
an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 60." and the horizontal
run to the wall flange of the vent termination is 84",
this would
NOT be an acceptable installation�
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and
the horizontal run to the wall flange of the vent termination is 120",
this would NOT be an acceptable installation�
53”
42”
33”
12”
B
C
A
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
If your installation does not fall within
the venting graph parameters, please
contact a local Montigo dealer for
Power Venting options.
Figure 15
.
H38PF* , HL38PF* or HP38PF* Straight run, Rear Vented
, wall
mounted termination. The vent run must comply with the Venting Graph for
Rear vent, wall mounted
terminations,
Figure 14 or 14a.
Hearth
12”
MAX.
Heat
Shield
Termination
Exterior
Wa
ll
33”
NOTE: 12” MAX�
horizontal run with
no vertical lift�
42”
60”
A
C
B
Acceptable vent run
within non-shaded area.
Unacceptable vent run
within shaded area.
12”
33”
If your installation does not fall within
the venting graph parameters, please
contact a local Montigo dealer for
Power Venting options.