Page 21
XG0816 - 150204.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 6: Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in
Figure 22
.
Fireplace Facing
When sizing the finish material for your fireplace, it is important to
remember the following:
THE OPENING MUST NOT BE OBSTRUCTED
IN ANY WAY - to do so restricts the air supply for the control
compartments and heat exchanger it also prevents access for
servicing controls�
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.
Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
Side wall clearances are 3". Combustible surrounds may be installed
with 3" clearance to the side of the fireplace.
Do not operate this fireplace without the glass door or with a broken glass door.
NOTICE
Do not use ammonia based or abrasive cleaners on the glass, they will permanently
etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or
White off.
NOTICE
WARNING!
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discolouration or premature failure of T.V.
radio, and other electronic components.
WARNING!
When covering the upper metal portion of the fireplace, up to 4"
(
as shown,
Fig.22
) with a non-combustible material
Please Note
:
The decorative facing materials may be subject to temperatures
in excess of 250° F. This should be considered when selecting
facing materials.
Combustible
Construction allowed
in shaded area
Top of fireplace
4” Nailing flange
Combustible Facing
Material
Horizontal Run (in)
Vertica
l
Run (in)
Steel Stud construction
allowable within grey area
Figure 22�
Combustible mantels and facings.
Figure 23�
Combustible surrounds.
WARNING
Do not place any materials or objects on top of the
valve blind. Doing so could result in failure of door
relief system or heat dissipation.
4” Nailing Flange
Drywall/Sheetrock
3”
Header