The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a 

ten-year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the pilot burner, gas control valve and 

fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas 

Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance 

could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building 

codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of  Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materi-

als, specifications, prices and also to discontinue colors, styles and products.

Warranty

Summary of Contents for BF36-SS

Page 1: ...ion adjustment alteration serviceormaintenancecancauseinjury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor...

Page 2: ...ions contained in this Installation Operations and Maintenance manual Pay special attention to all cautions warnings and Important warnings This owner s manual should be retained for future reference We suggest that you keep it with all your other important documents and product manuals The information contained in this owner s manual unless noted other wise applies to all models and gas control s...

Page 3: ... correct vent run and air supply information to the Engineering staff of Montigo After this initial consultation with Montigo we will specify the correct power vent model for your project The fireplace can be installed on any combustible platform as there will be no heat transfer to the base of the fireplace Fresh Air Supply Connect all of the fresh air supply for this fireplace to the lower vent ...

Page 4: ...oom traffic has adequate ventilation and offers an accessible pathway for vent installation Refer to Vent Installation Section for more information Please refer to the dimensions below and the clearances on the fol lowing pages when selecting the location of your fireplace 35 875 27 875 9 750 39 120 44 000 28 000 34 020 12 000 31 120 66 050 4 520 26 060 7 125 20 340 11 830 35 875 27 875 9 750 39 1...

Page 5: ...Framing dimensions and clearances to combustibles Framing Single SIded Unit Figure 3 Framing dimensions side view W 108 Y X Z X1 X W 108 Y X Z X1 X Figure 2 Framing dimensions and clearances to combustibles Figure 3 Framing dimensions side view W X X1 Y Z BF 36 SS 94 48 73 64 27 BF 36 ST 94 48 73 64 27 ...

Page 6: ...ble for test gauge connection immediately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable brick panel in the centre of the unit It only needs to be attached to the gas line with an approved fitting as required by the applicable installation codes The appliance and its individual shutoff valve must be...

Page 7: ...replace is equipped with a 20 foot low voltage wire for connecting to a wall switch of your choice longer lengths are an option Figure 7 Electrical Supply 110V Power Supply Power Vent Motor Gas Control Wiring Wall Switch Air Proving Switch Fuse Fan Speed Control Post Purge Control Vent Terminations Selecting A Termination Location Before installing the termination or venting check to ensure the pl...

Page 8: ...atedundertheburners willmonitorthecombustion air supply pressure and will prevent the burner from igniting or continuing to burn if the pressure is negative past 0 08WC For extremely long air supply runs the combustion air supply will have to be power assisted Figure 7b BF SS Standard Control Box Power Vent Control Box Wiring requirements for Power Vent Installation Power Vent Termination Power Ve...

Page 9: ...mart Valve No 1 as well as terminal 3 and 4 with relay R2 activating Smart Valve No 2 7 The Smart Valve system will light the pilotand by proving the pres ence of a pilot flame it will fire up the burners After the third failure to establish a pilot the valve will lock out 8 To reset the system turn the wall switch off and then back on First Burner 1 2 Black White Second Burner 3 4 Blue Yellow Wal...

Page 10: ...he 10 24 screws counterclockwise Note Have someone hold the door window assembly in place until all screws are removed Then grab the assembly from either end lifting it away from the fireplace Place it in a safe location to store or clean Figure17 Step4 Removaliscomplete Proceedwithserviceorcleaning installing the door Install the door in reverse order as shown in Steps 1 through 4 Important whenr...

Page 11: ...ll look like shown in figure 27f Figure 27f Completed Logset Step 2 Place the longest bottom 2 logs length wise on the log grate as shown in figure27a Ensure the charcoal colour is faces down the indents facing up and opposite each other Indents are for positioning the next log see figure 27b Figure 27a Bottom Rear Log Log A Figure 27b Centre log placement Step 3 Place the second longest centre lo...

Page 12: ...e opening at all because it will interfere with the access to retainers for removal of glass door Figure 14 Combustible mantles and facings W O Door Figure 15 Combustible surrounds Fireplace Facing With Door When selecting the finish material for your fireplace it is important to remember the following The face of the fireplace may be painted to match the room decor provided you use a heat resista...

Page 13: ...t try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove the lower Horizontal access panel 3 Turn the switch on the gas control to Off 4 Replace the lower Horizontal access panel 1 STOP Read the safety information above on...

Page 14: ...rner and firebox free from dust and lint Logs may be cleaned periodically with a vacuum to remove soot or other contaminates Figure 16 Honeywell SV9501 gas valve Troubleshooting If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are avai...

Page 15: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Page 16: ...e grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless ...

Page 17: ...Page 17 BF36 SS and ST Gas Fireplace Part No XG0712 031811 f i r e f e a t u r e Notes ...

Page 18: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0712 031811 f i r e f e a t u r e ...

Reviews: