BF36 SS and ST Gas Fireplace

Part No. XG0712 - 031811

f i r e    f e a t u r e 

 

                   

                       

 

Amendment

 

 

 

  (Gas Fireplace / Equipment sold in the State of Massachusetts)

 

 

 

 

   5.08: Modifications to NFPA-54, Chapter 10

 

(1) Revise NFPA-54 section 10.5.4.2

 

by adding a second exception as follows:

Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device 

that will automatically shut off the gas to the burner in the event of a sustained back-draft

.

 

(2) Revise 10.8.3

 by 

adding the following additional requirements:

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, 

including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in 

the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 

 

1. INSTALLATION OF CARBON MONOXIDE DETECTORS.

 

At the time of installation of the side wall horizontal vented gas fueled equip-

ment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor 

level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon 

monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled 

equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon 

monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with 

alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days 

to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm 

shall be installed.

 

2. APPROVED CARBON MONOXIDE DETECTORS.

 

Each carbon monoxide detector as required in accordance with the above provisions 

shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 

 

3. SIGNAGE.

 

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet 

above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print 

size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

 

4. INSPECTION.

 The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, 

upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. 

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 

 

1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the 

Board; and 

 

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or struc-

ture used in whole or in part for residential purposes.  

 

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED

. When the manufacturer of Product 

Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions 

provided by the manufacturer for installation of the equipment and the venting system shall include:

 

1. Detailed instructions for the installation of the venting system design or the venting system components; and

 

2. A complete parts list for the venting system design or venting system. 

 

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED

. When the manufacturer of a Prod-

uct Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, 

the following requirements shall be satisfied by the manufacturer:

 

1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 

 

2. The “special venting systems”

 shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 

detailed installation instructions. 

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for 

venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

 

(3) After NFPA-54 section 10.10.4.2

 add a new section 10.10.4.3 as follows:

When more than four gas appliances are to be vented through a common gas vent or common horizontal vent manifold, a plan of the proposed vent installation 

shall be submitted to the Inspector and the serving gas supplier for review and approval.

Extraction from: Massachusets Rules and Regulations

5.00: Amendments To 2002 Edition Of ANSI Z223.1-NFPA-54

Appendix B - State of  Massachusetts

Summary of Contents for BF36-SS

Page 1: ...ion adjustment alteration serviceormaintenancecancauseinjury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor...

Page 2: ...ions contained in this Installation Operations and Maintenance manual Pay special attention to all cautions warnings and Important warnings This owner s manual should be retained for future reference We suggest that you keep it with all your other important documents and product manuals The information contained in this owner s manual unless noted other wise applies to all models and gas control s...

Page 3: ... correct vent run and air supply information to the Engineering staff of Montigo After this initial consultation with Montigo we will specify the correct power vent model for your project The fireplace can be installed on any combustible platform as there will be no heat transfer to the base of the fireplace Fresh Air Supply Connect all of the fresh air supply for this fireplace to the lower vent ...

Page 4: ...oom traffic has adequate ventilation and offers an accessible pathway for vent installation Refer to Vent Installation Section for more information Please refer to the dimensions below and the clearances on the fol lowing pages when selecting the location of your fireplace 35 875 27 875 9 750 39 120 44 000 28 000 34 020 12 000 31 120 66 050 4 520 26 060 7 125 20 340 11 830 35 875 27 875 9 750 39 1...

Page 5: ...Framing dimensions and clearances to combustibles Framing Single SIded Unit Figure 3 Framing dimensions side view W 108 Y X Z X1 X W 108 Y X Z X1 X Figure 2 Framing dimensions and clearances to combustibles Figure 3 Framing dimensions side view W X X1 Y Z BF 36 SS 94 48 73 64 27 BF 36 ST 94 48 73 64 27 ...

Page 6: ...ble for test gauge connection immediately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable brick panel in the centre of the unit It only needs to be attached to the gas line with an approved fitting as required by the applicable installation codes The appliance and its individual shutoff valve must be...

Page 7: ...replace is equipped with a 20 foot low voltage wire for connecting to a wall switch of your choice longer lengths are an option Figure 7 Electrical Supply 110V Power Supply Power Vent Motor Gas Control Wiring Wall Switch Air Proving Switch Fuse Fan Speed Control Post Purge Control Vent Terminations Selecting A Termination Location Before installing the termination or venting check to ensure the pl...

Page 8: ...atedundertheburners willmonitorthecombustion air supply pressure and will prevent the burner from igniting or continuing to burn if the pressure is negative past 0 08WC For extremely long air supply runs the combustion air supply will have to be power assisted Figure 7b BF SS Standard Control Box Power Vent Control Box Wiring requirements for Power Vent Installation Power Vent Termination Power Ve...

Page 9: ...mart Valve No 1 as well as terminal 3 and 4 with relay R2 activating Smart Valve No 2 7 The Smart Valve system will light the pilotand by proving the pres ence of a pilot flame it will fire up the burners After the third failure to establish a pilot the valve will lock out 8 To reset the system turn the wall switch off and then back on First Burner 1 2 Black White Second Burner 3 4 Blue Yellow Wal...

Page 10: ...he 10 24 screws counterclockwise Note Have someone hold the door window assembly in place until all screws are removed Then grab the assembly from either end lifting it away from the fireplace Place it in a safe location to store or clean Figure17 Step4 Removaliscomplete Proceedwithserviceorcleaning installing the door Install the door in reverse order as shown in Steps 1 through 4 Important whenr...

Page 11: ...ll look like shown in figure 27f Figure 27f Completed Logset Step 2 Place the longest bottom 2 logs length wise on the log grate as shown in figure27a Ensure the charcoal colour is faces down the indents facing up and opposite each other Indents are for positioning the next log see figure 27b Figure 27a Bottom Rear Log Log A Figure 27b Centre log placement Step 3 Place the second longest centre lo...

Page 12: ...e opening at all because it will interfere with the access to retainers for removal of glass door Figure 14 Combustible mantles and facings W O Door Figure 15 Combustible surrounds Fireplace Facing With Door When selecting the finish material for your fireplace it is important to remember the following The face of the fireplace may be painted to match the room decor provided you use a heat resista...

Page 13: ...t try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove the lower Horizontal access panel 3 Turn the switch on the gas control to Off 4 Replace the lower Horizontal access panel 1 STOP Read the safety information above on...

Page 14: ...rner and firebox free from dust and lint Logs may be cleaned periodically with a vacuum to remove soot or other contaminates Figure 16 Honeywell SV9501 gas valve Troubleshooting If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are avai...

Page 15: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Page 16: ...e grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless ...

Page 17: ...Page 17 BF36 SS and ST Gas Fireplace Part No XG0712 031811 f i r e f e a t u r e Notes ...

Page 18: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0712 031811 f i r e f e a t u r e ...

Reviews: