background image

Page 10

BF36 SS and ST Gas Fireplace

Part No. XG0712 - 031811

f i r e    f e a t u r e 

Figure 8.

 

Step 1. (Door Trim )

Figure 8a.

 

Step 2. (removal of Trim)

Figure 8b.

 Step 3 (Removal of  Door 

Frame)

Figure 8c.

 (Completed  Removal)

Removing and Installing

 the Door

Removing the door:

The 

BF-SS

 Door-Window outer trim is held in place by magnets, and 

the Door-window frame are held in place by fine-thread 10-24 screws.  

Follow the process below to remove, or install the items described.

Figure 14

. The Fireplace as it is received from Montigo. 

Figure 15

.

 (Step 2)

 Remove the Door-window trim by grasping the metal 

firmly and pull it free it from the frame. 

Note: Hold it as shown in Step 2 

to release the hold of the magnets. 

Figure 16

(Step 3)

  Remove the Door-window assembly by turning the 

10-24 screws counterclockwise. Note: Have someone hold the door-

window assembly in place until all screws are removed. Then grab the 

assembly from either end lifting it away from the fireplace. Place it in a 

safe location to store or clean.

Figure 17

(Step 4) 

Removal

 

is complete. Proceed with service or cleaning.

installing the door:

Install the door in reverse order as shown in Steps 1 through 4. 
Important: when re-installing screws into their original location,  ALWAYS 

hand tighten with screwdriver to ensure proper tension on all screws.

Installation

    Cautions: 

 

Fireplace gas control must be in the “OFF” position and pilot 

and main burners extinguished when cleaning appliance 

with a vacuum. 

 

 

 Doors and logs can get very hot. Handle only when cool.

    WARNING!

Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass etching 

may cause premature glass failure.
Do not operate this fireplace without the glass door, or with a 

broken glass door.

Summary of Contents for BF36-SS

Page 1: ...ion adjustment alteration serviceormaintenancecancauseinjury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor...

Page 2: ...ions contained in this Installation Operations and Maintenance manual Pay special attention to all cautions warnings and Important warnings This owner s manual should be retained for future reference We suggest that you keep it with all your other important documents and product manuals The information contained in this owner s manual unless noted other wise applies to all models and gas control s...

Page 3: ... correct vent run and air supply information to the Engineering staff of Montigo After this initial consultation with Montigo we will specify the correct power vent model for your project The fireplace can be installed on any combustible platform as there will be no heat transfer to the base of the fireplace Fresh Air Supply Connect all of the fresh air supply for this fireplace to the lower vent ...

Page 4: ...oom traffic has adequate ventilation and offers an accessible pathway for vent installation Refer to Vent Installation Section for more information Please refer to the dimensions below and the clearances on the fol lowing pages when selecting the location of your fireplace 35 875 27 875 9 750 39 120 44 000 28 000 34 020 12 000 31 120 66 050 4 520 26 060 7 125 20 340 11 830 35 875 27 875 9 750 39 1...

Page 5: ...Framing dimensions and clearances to combustibles Framing Single SIded Unit Figure 3 Framing dimensions side view W 108 Y X Z X1 X W 108 Y X Z X1 X Figure 2 Framing dimensions and clearances to combustibles Figure 3 Framing dimensions side view W X X1 Y Z BF 36 SS 94 48 73 64 27 BF 36 ST 94 48 73 64 27 ...

Page 6: ...ble for test gauge connection immediately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable brick panel in the centre of the unit It only needs to be attached to the gas line with an approved fitting as required by the applicable installation codes The appliance and its individual shutoff valve must be...

Page 7: ...replace is equipped with a 20 foot low voltage wire for connecting to a wall switch of your choice longer lengths are an option Figure 7 Electrical Supply 110V Power Supply Power Vent Motor Gas Control Wiring Wall Switch Air Proving Switch Fuse Fan Speed Control Post Purge Control Vent Terminations Selecting A Termination Location Before installing the termination or venting check to ensure the pl...

Page 8: ...atedundertheburners willmonitorthecombustion air supply pressure and will prevent the burner from igniting or continuing to burn if the pressure is negative past 0 08WC For extremely long air supply runs the combustion air supply will have to be power assisted Figure 7b BF SS Standard Control Box Power Vent Control Box Wiring requirements for Power Vent Installation Power Vent Termination Power Ve...

Page 9: ...mart Valve No 1 as well as terminal 3 and 4 with relay R2 activating Smart Valve No 2 7 The Smart Valve system will light the pilotand by proving the pres ence of a pilot flame it will fire up the burners After the third failure to establish a pilot the valve will lock out 8 To reset the system turn the wall switch off and then back on First Burner 1 2 Black White Second Burner 3 4 Blue Yellow Wal...

Page 10: ...he 10 24 screws counterclockwise Note Have someone hold the door window assembly in place until all screws are removed Then grab the assembly from either end lifting it away from the fireplace Place it in a safe location to store or clean Figure17 Step4 Removaliscomplete Proceedwithserviceorcleaning installing the door Install the door in reverse order as shown in Steps 1 through 4 Important whenr...

Page 11: ...ll look like shown in figure 27f Figure 27f Completed Logset Step 2 Place the longest bottom 2 logs length wise on the log grate as shown in figure27a Ensure the charcoal colour is faces down the indents facing up and opposite each other Indents are for positioning the next log see figure 27b Figure 27a Bottom Rear Log Log A Figure 27b Centre log placement Step 3 Place the second longest centre lo...

Page 12: ...e opening at all because it will interfere with the access to retainers for removal of glass door Figure 14 Combustible mantles and facings W O Door Figure 15 Combustible surrounds Fireplace Facing With Door When selecting the finish material for your fireplace it is important to remember the following The face of the fireplace may be painted to match the room decor provided you use a heat resista...

Page 13: ...t try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove the lower Horizontal access panel 3 Turn the switch on the gas control to Off 4 Replace the lower Horizontal access panel 1 STOP Read the safety information above on...

Page 14: ...rner and firebox free from dust and lint Logs may be cleaned periodically with a vacuum to remove soot or other contaminates Figure 16 Honeywell SV9501 gas valve Troubleshooting If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are avai...

Page 15: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Page 16: ...e grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless ...

Page 17: ...Page 17 BF36 SS and ST Gas Fireplace Part No XG0712 031811 f i r e f e a t u r e Notes ...

Page 18: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0712 031811 f i r e f e a t u r e ...