7
8
9
1
•
888
•
557
•
3848
Wards.com
Operating Instructions
(cont’d)
Operating Instructions
(cont’d)
Foot Holder
Remove:
Remove the thumb screw (1) by
turning it counterclockwise with
a screwdriver.
Attach:
1. Match the hole in the foot
holder (2) with the threaded
hole in the presser bar (3).
2. Fit the thumb screw (1) into
the hole.
3. Tighten the screw by turning it clockwise with screwdriver.
Needles
Before changing needles, confirm that they are not bent or warped. Place the
flat side of the needle on something flat (needle plate, glass etc.). The clearance
between the needle and flat surface should be consistent. Never use a bent or
blunt needle.
Changing:
1. Raise the needle by turning the
handwheel toward you.
2. Lower the presser foot.
3. Loosen the needle clamp screw
by turning it counterclockwise.
4. Remove the needle from the
clamp.
5. Insert the new needle into the
clamp with the flat side away from
you.
6. Push it up as far as it will go and
tighten the clamp screw firmly with
the screwdriver.
Spool Pins
The spool pins are used for holding the spool of thread in order to feed it to the ma-
chine. To use, pull the spool pin up. Push down to store.
Bobbin Case
Inserting or removing:
Open hook cover (1).
Raise the needle by turning the handwheel toward you. Take out the bobbin case by
holding the latch (2). Insert the bobbin case by placing the horn (3) into the recess
of the hook race.