If a reversed polarity warning is indicated, DO NOT USE
the generator. Immediately turn off the generator and
determine the source of the problem. Reversed polarity
is a dangerous and potentially lethal condition which
may cause shock, electrocution, or death.
Shore Power Light
– Indicates that shore power is being received
by the AC control panel.
To Operate From Shore Power
1. Shut down generator if applicable. If equipped, Generator
Running indicator will go out.
2. Turn “OFF” generator breaker and main AC breaker. If equipped,
Power Available indicator will go out.
3. If so equipped, move the slide protector over the Generator
breaker.
4. Flip the Shore Power breaker to the “ON” position. The Power
Available indicator should illuminate.
5. Flip the Main AC breaker to the “ON” position. If the Reversed
Polarity light illuminates, flip the breaker “OFF” immediately.
If a reversed polarity warning is indicated, DO NOT USE
the shore power source. Immediately turn off the power
source on shore and disconnect the shore power cord.
Reversed polarity is a dangerous and potentially lethal
condition which may cause shock, electrocution, or
death.
6. Flip individual circuit breakers “ON” as required.
To Operate From Generator Power
1. Shut down shore power if applicable. If equipped, Shore Power
indicator will go out.
2. Turn “OFF” shore power breaker and main AC breaker. If
equipped, Power Available indicator will go out.
3. If so equipped, move the slide protector over the Shore Power
breaker.
4. Flip the Generator breaker to the “ON” position. The Power
Available indicator should illuminate.
5. Flip the Main AC breaker to the “ON” position. If the Generator
Reversed Polarity light illuminates, flip the breaker “OFF” imme-
diately.
If a reversed polarity warning is indicated, DO NOT USE
the generator power source. Immediately turn off the
power source. Reversed polarity is a dangerous and
potentially lethal condition which may cause shock,
electrocution, or death.
6. Flip individual circuit breakers “ON” as required.
!
WARNING
!
!
WARNING
!
!
WARNING
!
SHIP SYSTEMS
11-7
Summary of Contents for 268 SC Sport Cruiser
Page 4: ......
Page 15: ...M 11 VECTOR SERIES AIR CONDITIONER SELF CONTAINED UNIT WIRING DIAGRAM...
Page 29: ...M 25 Use ATC series fuses 268 Bowrider and Cuddy Starboard Switch Panel Wiring Diagram...
Page 30: ...M 26 268 Bowrider and Cuddy Ignition Panel Wiring Diagram...
Page 31: ...M 27 268 Bowrider and Cuddy Instrument Panel Wiring Diagram...
Page 32: ...M 28 268 Bowrider and Cuddy DC Wiring Diagram Main...
Page 33: ...M 29 298 Bowrider AC Wiring Diagram Main 1 of 3...
Page 35: ...M 31 298 Bowrider Water System...
Page 36: ...M 32 298 Cuddy DC Wiring Diagram Main 1 of 5...
Page 37: ...M 33 298 Bowrider DC Wiring Diagram Main 2 of 5...
Page 78: ...OPERATION 4 10...
Page 90: ...6 RUNNING 6 8...
Page 106: ...STORAGE 9 4...