28
IMPORTANT: WHEN INSTALLING BLOWER WHEEL ON MOTOR SHAFT, POSITION
BLOWER WHEEL SO THAT IT WILL NOT RUB AGAINST BOLT HEADS ON MOUNTING
PLATE OR CONTACT FAN BAFFLE.
MOTORS
The following is used on the oven:
ELECTRICAL CHARACTERISTICS
PART NO. MFR HP SPEED
VOLTAGE HZ
PH
06382-7
Baldor 1/4 1
115/230
60
1
DOOR SWITCH
CAUTION
DISCONNECT ELECTRICAL POWER TO RANGE BEFORE SERVICING
The switch should be adjusted to so that when the door is opened one-quarter inch, the switch
shuts off the blower. The switch is located behind the burner access panel on the right side next to
the door post.
ADJUSTMENT
1. Loosen the two nuts on front of door switch bracket.
2. Turn back-up nuts inward to increase opening to 1-1/4 or turn back-up nuts outward to
decrease opening. With no power on oven, the switch is adjusted by the sound of the switch
clicking.
REPLACEMENT
1. Remove switch cover.
2. Carefully disconnect wires from switch.
3. Remove nuts from microswitch mounting screws.
4. Follow above steps in replacing parts in reverse order.
CAUTION
Check that washers are in place between microswitch and bracket and the insulated terminal
(without wire lead) is replaced on NC terminal of microswitch.
5. Adjust microswitch operation as described in ADJUSTMENT.