10
ELECTRICAL CONNECTION
Unless otherwise specified, the range is
equipped with a 6 ft. flexible supply cord for 115
VAC, 60 or 50 Hertz, single phase units. The
wiring diagram is located on the back of the
range.
NOTE
:
THIS
APPLIANCE
WHEN
INSTALLED, MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL
CODES, OR IN THE ABSENCE OF LOCAL
CODES, WITH THE NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70-1984.
I.
115 VAC - 60 Hz - SINGLE PHASE
Ranges with this electrical rating are factory
supplied with a three wire cord and three prong
plug which fits any standard three prong
grounded receptacle. a separate 15 amp. supply
is needed for each oven.
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A
THREE PRONG (GROUNDING) PLUG FOR
YOUR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED
THREE PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG
FROM THIS PLUG.
ll.
208-240 VAC - 60 Hz - SINGLE PHASE
(2 WIRE)
Ranges with this electrical rating are factory
equipped with a terminal block. To connect
supply wires, remove cover from connection box
at right rear of range. Route supply wires and
ground wire through hole with strain relief fitting
at top of connection box. Attach supply wires to
proper terminal of terminal block. Attach ground
wire to ground lug inside connection box. See
wiring diagram for proper connection.
lll.
220 VAC - 50 Hz - SINGLE PHASE
(2 WIRE)
Follow steps outlined in ( ll. ) Refer to wiring
diagram for proper connection.