TROUBLE SHOOTING TIPS

CAUTION :

  

As failures or errors occur, please use the following table to try 
and fix the device. If the device remains problematic, please send 
back to the manufacturer for repair.

Federal law restricts this device to sale or on the order of a dentist.

DESCRIPTIONS

The red and green 
signal lights of 
charger stand are 
unable to light up

Poor connection 
between plug and 
cable

Check the connection 
between plug and 
cable

LCD device is 
unable to light up

Defect in LCD 
device or pc board

Return to 
manufacturer / agent 
for repair

No activation 

Lithium-ion 
battery is defective

FAILURE                   

CAUSE                        SOLUTION

Return to 
manufacturer / agent 
for repair

Defect in charger

Defect in main IC 
board

LED lamp is unable
to emit

Defect in LED 
module

SPECIFICATION

CURING HANDPIECE :

LED LAMP : 5 Watt.

LIGHT INTENSITY : up to 1,500 mW/cm

WAVE LENGTH : 450 ~ 470 nm

DIMENSION : 18.5(L) x 3.86(W) x 8.2(H) cm

WEIGHT : APPROX. 206g

CHARGER :

OUTPUT VOLTAGE : 8.4 V (TYPICAL)

DIMENSION : 19.3(L) X 8.38(W) X 9.59(H) cm

WEIGHT : APPROX. 177 g

BATTERY :

LI-ION BATTERY PACK : 1 PC

VOLTAGE : 7.4 V (TYPICAL)

CAPACITY : 1,350 mAh (TYPICAL)

DIMENSION :  Approx. 1.8 x 6.5 cm

WEIGHT :  Approx. 78 g

ADAPTOR :

INPUT : AC100 V ~ 240 V  50/60 Hz

OUTPUT : DC 9 V

CURRENT : 1.3 A (TYPICAL)

LIGHT GUIDE :

FIBER OPTIC WITH TAPERED TIP

      10mm taper to    8mm

AUTOCLAVABLE UP TO 134 

°

C

2

E

N

G

L

IS

H

8

9

Summary of Contents for Ti-Lite GT-1500

Page 1: ...User Manual The innovative cordless LED curing light...

Page 2: ...Contents PREFACE 1 DISCLAIMER 1 SAFETY PRECAUTIONS 2 PARTS AND FUNCTIONS 3 GENERAL INSTALLATION 4 WARNING LI ION BATTERY 5 OPERATION 5 COOLING SYSTEM 7 CHARGER SIGNALS 7 TROUBLE SHOOTING TIPS 8 SPECIF...

Page 3: ...ersonal bodily injury is caused by the use of this product in conjunction with other regulated products 3 The manufacturer shall not assume any responsibility if any malfunction damage or accident of...

Page 4: ...r Fiber Optic Tip After operation on each patient the fiber optic tip should be disinfected or sterilized Suggestion is to use autoclave 134 C 75 psi for maximum result The sterilization time at 134 C...

Page 5: ...ing button M1 Full Power M2 Bleaching M3 Pulse Time setting button Charge stand AC 100V 240V 50 60Hz Built in radiometer Fiber optic probe Anti glare cone Protective Shield LCD display ON OFF SET on o...

Page 6: ...ce the handpiece in the charger stand to begin the initial charging as the red CHARGE led is lit 4 Put on the anti glare cone and the protective shield 5 Adjust the cone and shield position according...

Page 7: ...ry from locking out leaking heat generation or explosion please observe the following precautions Do not disassemble Keep the battery dry Keep away from high temperature Do not crush Please charge the...

Page 8: ...in ON OFF SET button to stop operation at any time 3 Auto Power Saving Mode the device will turn off automatically if it is left idled for longer than 90 seconds Operation resumes once the user presse...

Page 9: ...n up right position to begin charging 2 When the charger starts charging the red CHARGE light will be turned on to indicate the charging begins 3 The green READY light resumes after the handpiece is f...

Page 10: ...RIPTIONS The red and green signal lights of charger stand are unable to light up Poor connection between plug and cable Check the connection between plug and cable LCD device is unable to light up Def...

Page 11: ...LTAGE 8 4 V TYPICAL DIMENSION 19 3 L X 8 38 W X 9 59 H cm WEIGHT APPROX 177 g BATTERY LI ION BATTERY PACK 1 PC VOLTAGE 7 4 V TYPICAL CAPACITY 1 350 mAh TYPICAL DIMENSION Approx 1 8 x 6 5 cm WEIGHT App...

Page 12: ...ONG SEC 1 CITY 24158 TAIPEI COUNTY TAIWAN TEL 886 2 29993869 FAX 886 2 29993647 E mail monitex monitex com tw http www monitex com tw INDUSTRIAL CO LTD 2010 08 Ver 1 Copyright 2010 MONITEX Industrial...

Reviews: