PARTS & FUNCTIONS

Body cover

3 modes setting button:        

M1

 - Full Power 

M2

 - Bleaching 

M3

 - Pulse

Time setting button

Charge stand 
(

AC 100V~240V 50/60Hz)

Built in radiometer 

Fiber optic probe

Anti-glare cone

Protective Shield

LCD display

ON / OFF / SET
(on/off, set/memory)

Charging socket

SAFETY PRECAUTIONS

Please follow instruction steps in this manual for correct and 
safe operations of the device. Pay high attention to the following 
warning signs beside the operation descriptions where applicable.

DANGER

 

 

This message appears where the operation may potentially 

                        cause severe injury if instruction not followed correctly.

WARNING

 

 

This message appears where the operation may cause 

                          serious damage or defect to other objects.

CAUTION

 

 

This message appears where the operation may cause 

                         slight damage to other objects or slight bodily harm if 
                         operation not properly conducted.

IMPORTANT

 

 

This message appears where the operation may involve 

                             risk of defecting the device itself  if not properly 
                             conducted.

Sterilization for Fiber-Optic Tip:

After operation on each patient, the fiber-optic tip should be disinfected 
or sterilized.  Suggestion is to use autoclave 134

°

C / 75 psi for maximum 

result.  The sterilization time at 134

°

C should be 5 minutes.

Note:

 Please disconnect the fiber-optic tip off the handpiece and 

           autoclave by itself.

Note:

 Use of disposable sleeves is recommended.

Product Cleaning:

If there is any dirt or stains on the surface of control panel or surface 
of the handpiece, please use cloth to wipe clean.  If it is hard to clean, 
please use a neutral cleansing agent.

Note:

 Never use a solvent or volatile oil for cleaning.  This can 

           lead to fading in the fiber optic shades.

Symbol

Explantion

Type B applied part

Attention, consult
ACCOMPANYING DOCUMENTS

Signifies the device has meet all essential requirements of 
European Medical Device Directive 93/42/EEC & 2007/47/EEC.

Symbol used to indicate the polarity of the DC power input.

Direct Current

E

N

G

L

IS

H

2

3

Summary of Contents for Ti-Lite GT-1500

Page 1: ...User Manual The innovative cordless LED curing light...

Page 2: ...Contents PREFACE 1 DISCLAIMER 1 SAFETY PRECAUTIONS 2 PARTS AND FUNCTIONS 3 GENERAL INSTALLATION 4 WARNING LI ION BATTERY 5 OPERATION 5 COOLING SYSTEM 7 CHARGER SIGNALS 7 TROUBLE SHOOTING TIPS 8 SPECIF...

Page 3: ...ersonal bodily injury is caused by the use of this product in conjunction with other regulated products 3 The manufacturer shall not assume any responsibility if any malfunction damage or accident of...

Page 4: ...r Fiber Optic Tip After operation on each patient the fiber optic tip should be disinfected or sterilized Suggestion is to use autoclave 134 C 75 psi for maximum result The sterilization time at 134 C...

Page 5: ...ing button M1 Full Power M2 Bleaching M3 Pulse Time setting button Charge stand AC 100V 240V 50 60Hz Built in radiometer Fiber optic probe Anti glare cone Protective Shield LCD display ON OFF SET on o...

Page 6: ...ce the handpiece in the charger stand to begin the initial charging as the red CHARGE led is lit 4 Put on the anti glare cone and the protective shield 5 Adjust the cone and shield position according...

Page 7: ...ry from locking out leaking heat generation or explosion please observe the following precautions Do not disassemble Keep the battery dry Keep away from high temperature Do not crush Please charge the...

Page 8: ...in ON OFF SET button to stop operation at any time 3 Auto Power Saving Mode the device will turn off automatically if it is left idled for longer than 90 seconds Operation resumes once the user presse...

Page 9: ...n up right position to begin charging 2 When the charger starts charging the red CHARGE light will be turned on to indicate the charging begins 3 The green READY light resumes after the handpiece is f...

Page 10: ...RIPTIONS The red and green signal lights of charger stand are unable to light up Poor connection between plug and cable Check the connection between plug and cable LCD device is unable to light up Def...

Page 11: ...LTAGE 8 4 V TYPICAL DIMENSION 19 3 L X 8 38 W X 9 59 H cm WEIGHT APPROX 177 g BATTERY LI ION BATTERY PACK 1 PC VOLTAGE 7 4 V TYPICAL CAPACITY 1 350 mAh TYPICAL DIMENSION Approx 1 8 x 6 5 cm WEIGHT App...

Page 12: ...ONG SEC 1 CITY 24158 TAIPEI COUNTY TAIWAN TEL 886 2 29993869 FAX 886 2 29993647 E mail monitex monitex com tw http www monitex com tw INDUSTRIAL CO LTD 2010 08 Ver 1 Copyright 2010 MONITEX Industrial...