background image

Time Setting :

1. Once the user sets the mode (

M1

 or 

M3

), please press 

TIME

 button 

    continuously for longer than 2 seconds (till the number shown in the  LCD 
    panel starts to blink), and press again to change time, one second per push. 

2. (

M1

 and 

M3

) Operating time will start to add up after one second if 

    the user pushes the TIME button continuously. Press  

ON/OFF/SET 

    button to complete time setting. 

3. The time setting of 

M2

 is for 15 minutes which can not be re-set.

Operation :

1. After setting up the MODE selection and operating time, 
    triggers the 

ON/OFF/SET 

button to start curing cycle.

2. Press again 

ON/OFF/SET 

button to stop operation at any time.

3. Auto Power Saving Mode: the device will turn off automatically if it is left 
    idled for longer than 90 seconds. Operation resumes once the user presses 
    the trigger 

ON/OFF/SET

.

4. Under “

M1, 8 seconds

” setting, the device can be continuously ultilized 

    for approximately 30  curing sessions.

Caution : 

Operating GT-1500 at 

Mode 1

, 8 seconds for more than 30 cycles 

continuously could result in high temperature accumulation, which is 
hazardous to the patient’s teeth. The user should pay more caution to 
check if any over-heating or contraindication.

COOLING SYSTEM

Ti-Lite 

GT-1500

 is equipped with a special built-in magnetic fan 

motor to prevent over-heating and to prolong the light emitting time.

Radiometer Sensor :

1. Choose 

M1 

(full power)

2. Instert the Fiber-Optic tip to the handpiece.
3. Aim the tip at the 

Sensor of Radiometer

 and 

    press 

ON/OFF/SET

 button to start checking the 

    light intensity.

Over-heating
Indication

CHARGER SIGNALS

1. When the power of battery is low, place the handpiece onto 
    the charger stand in up-right position to begin charging.
2. When the charger starts charging, the 

red 

(CHARGE)

 

    light will be turned on to indicate the charging begins.
3. The 

green 

(READY)

 light resumes after the 

    handpiece is fully charged.

IMPORTANT :

> The cooling system will be
   activated with the motor fan 
   which starts turning when the 
   heat starts to accumulate.

> The thermometer symbol will
   start to blink and shut off the
   system for complete cooling
   and for protection purpose.

Full

Low

E

N

G

L

IS

H

6

7

Summary of Contents for Ti-Lite GT-1500

Page 1: ...User Manual The innovative cordless LED curing light...

Page 2: ...Contents PREFACE 1 DISCLAIMER 1 SAFETY PRECAUTIONS 2 PARTS AND FUNCTIONS 3 GENERAL INSTALLATION 4 WARNING LI ION BATTERY 5 OPERATION 5 COOLING SYSTEM 7 CHARGER SIGNALS 7 TROUBLE SHOOTING TIPS 8 SPECIF...

Page 3: ...ersonal bodily injury is caused by the use of this product in conjunction with other regulated products 3 The manufacturer shall not assume any responsibility if any malfunction damage or accident of...

Page 4: ...r Fiber Optic Tip After operation on each patient the fiber optic tip should be disinfected or sterilized Suggestion is to use autoclave 134 C 75 psi for maximum result The sterilization time at 134 C...

Page 5: ...ing button M1 Full Power M2 Bleaching M3 Pulse Time setting button Charge stand AC 100V 240V 50 60Hz Built in radiometer Fiber optic probe Anti glare cone Protective Shield LCD display ON OFF SET on o...

Page 6: ...ce the handpiece in the charger stand to begin the initial charging as the red CHARGE led is lit 4 Put on the anti glare cone and the protective shield 5 Adjust the cone and shield position according...

Page 7: ...ry from locking out leaking heat generation or explosion please observe the following precautions Do not disassemble Keep the battery dry Keep away from high temperature Do not crush Please charge the...

Page 8: ...in ON OFF SET button to stop operation at any time 3 Auto Power Saving Mode the device will turn off automatically if it is left idled for longer than 90 seconds Operation resumes once the user presse...

Page 9: ...n up right position to begin charging 2 When the charger starts charging the red CHARGE light will be turned on to indicate the charging begins 3 The green READY light resumes after the handpiece is f...

Page 10: ...RIPTIONS The red and green signal lights of charger stand are unable to light up Poor connection between plug and cable Check the connection between plug and cable LCD device is unable to light up Def...

Page 11: ...LTAGE 8 4 V TYPICAL DIMENSION 19 3 L X 8 38 W X 9 59 H cm WEIGHT APPROX 177 g BATTERY LI ION BATTERY PACK 1 PC VOLTAGE 7 4 V TYPICAL CAPACITY 1 350 mAh TYPICAL DIMENSION Approx 1 8 x 6 5 cm WEIGHT App...

Page 12: ...ONG SEC 1 CITY 24158 TAIPEI COUNTY TAIWAN TEL 886 2 29993869 FAX 886 2 29993647 E mail monitex monitex com tw http www monitex com tw INDUSTRIAL CO LTD 2010 08 Ver 1 Copyright 2010 MONITEX Industrial...

Reviews: