6
26D3311
26D3311
7
NATURAL GAS
Milli-Volt and T-Stat Pressure Hi/Lo Pressure
Regulator Pressure Setting: 3.5" w.c. Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c. Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c. Gas Inlet Pressure: Max. 11" w.c.
Min. 5" w.c.
Min. 6" w.c.
PRODUCT FEATURES
AND
SPECIFICATIONS
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Milli-Volt and T-Stat Pressure Hi/Lo Pressure
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c. Gas Inlet Pressure: Max. 13: w.c.
Min. 11" w.c.
Min. 12" w.c.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DIS33NTC MILLI-VOLT 28,000 18,000
DIS33NVC T-STAT 28,000 18,000
DIS33NHC HI/LO REMOTE 28,000 18,000
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Hi/Lo valve control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
PILOT
- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON.
HI/LOW
- Variable position corresponding to desired flame height back to pilot.
Milli-Volt and T-Stat control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI
- Variable position to control flame height (heat output). Both front and rear burners are in operation
to provide realistic glow and yellow flame.
PILOT
The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The milli-volt gas log pilot is fitted with a milli-volt generator to provide power for remote activation.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DIS33PTC MILLI-VOLT 28,000 20,000
DIS33PVC T-STAT 28,000 20,000
DIS33PHC HI/LO REMOTE 28,000 21,000