NOTE: COMBUSTIBLE MATERIALS SHOULD NOT BE INSTALLED BELOW TOP SPACER. NON-COMBU
NOTE: COMBUSTIBLE MATERIALS SHOULD NOT BE INSTALLED BELOW TOP SPACER. NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK OR TILE MAY BE USED TO TRIM FACE OF THE FIREPLACE BUT SHOULD NOT C
SUCH AS BRICK OR TILE MAY BE USED TO TRIM FACE OF THE FIREPLACE BUT SHOULD NOT COVER ANY PORTION OF THE
OVER ANY PORTION OF THE
LOUVERED PANEL OR COOL AIR INLET. COMBUSTIBLES MUST NOT OVERLAP THE BLACK PAINT
LOUVERED PANEL OR COOL AIR INLET. COMBUSTIBLES MUST NOT OVERLAP THE BLACK PAINTED FACE OF FIREPLACE.
CAUTION: DO NOT BLOCK AIR INLETS OR OUTLETS.
FIREPLACE - MODEL SCF42A OR SCF42AI SHOWN
RESIDENTIAL INSTALLATION
RESIDENTIAL INSTALLATION
TO COMBUSTIBLES MODEL:
CHIMNEY (2" MIN. AIR SPACE
44 1/2"
FRAMING
DIMENSION
FRAMING DIMENSIONS
FRONT - TO BACK
21 1/2"
COMBUSTION AIR
ASSEMBLY MODEL AK4
FLEXIBLE DUCT
TYPE FP-4-U
NAIL TO FRAMING MEMBERS
COOL AIR INLET (SEE CAUTION)
GD42B/GD42PB GLASS
DOOR ACCESSORY
WARM AIR OUTLET
(SEE CAUTION)
GALVANIZED METAL STRIP
TOP SPACER
S12 (1 FT. PIPE)
S18 (18 IN. PIPE)
S36 (3 FT. PIPE)
S48 (4 FT. PIPE)
SEE NOTE
FIRESTOP-MODEL SF
(REQUIRES 14 1/2 X 14 1/2 OPENING)
1 3/4" MIN. AIR SPACE TO COMBUSTIBLES)
STORM
COLLAR
ROOF FLASHING
MODEL 612
ROUND CHIMNEY CAP
MODEL SC
(BOTTOM OF FIREPLACE)
(FLUE OUTLET HEIGHT)
44"
FRAMING
DIMENSION
14 FT. = MIN. HEIGHT (NO OFFSETS)
14 FT. = MIN. HEIGHT (2-30˚ ELBOWS)
ELBOWS)
21 FT. = MIN. HEIGHT (4-30˚ ELBOWS)
ELBOWS)
86 FT. = MAX. HEIGHT (CHIMNEY
SUPPORT EVERY 30 FT.)
F
IGURE
1
6
C
LEARANCES
53D9032. Rev 1 03/03
Summary of Contents for BWB400 Series
Page 38: ...38 NOTES This page intentionally left blank 53D9031 Rev 1 03 03...
Page 39: ...NOTES 39 This page intentionally left blank 53D9031 Rev 1 03 03...
Page 78: ...38 THIS PAGE INTENTIONALLY LEFT BLANK 53D9032 Rev 1 03 03...
Page 79: ...39 THIS PAGE INTENTIONALLY LEFT BLANK 53D9032 Rev 1 03 03...