BDV7 Series Direct Vent Gas Fireplace
40
20301836
SIGNAtuRe CoMMAND SySteM oPeRAtIoN INStRuCtIoNS
SySteM CoNFIGuRAtIoN/SetuP
All System configuration/setup is done on the Command Center.
Note:
When using On/Off wall switch, the switch must be in the ON position to perform all configuration
set ups at the command center.
Intermittent/Standing Pilot Setup (Default intermittent)
1. Holding the ON button on the Command Center while turning on the master switch will toggle between
standing pilot and intermittent pilot.
2. After the above operation, one beep (for standing pilot) or two beeps (for intermittent pilot) will be given
as confirmation.
Six-hour Safety Shutdown option (Default oN)
1. The system comes preset from the factory with a six (6) hour shutdown from its last command of opera-
tion. This is done to prevent the fireplace from continuing to operate if unattended. You may disable this
feature if you wish.
Note:
By disabling this feature, your fireplace may continue to operate unattended.
2. When the master switch is in the ON position (“-”), pressing the ON button and the OFF button on the
Command Center simultaneously will toggle between enabling and disabling the six-hour shutdown op-
tion.
3. After the above operation, one beep (for enabling the six-hour shutdown option) or two beeps (for disabling
the six-hour shutdown option) will be given as confirmation.
Remote transmitter learn Function (Default oFF)
1. The RF receiver button located on the Control Board must be in the on position before the learn function
can begin. Use paper clip to depress button. One beep for RF receiver ON or two beeps for RF receiver
OFF will be given as confirmation. Refer to Figure 57 for location.
2. After the RF receiver is on, holding the OFF button on the Command Center while turning on the master
switch will activate the learn function for the transmitter.
3. After the above operation, two beeps will be given and the green LED on the Command Center will flash
for 10 seconds.
4. During the 10 seconds, press the OFF button on a transmitter to learn. Another two beeps will be given
to confirm a successful learning. Refer to transmitter instructions for remote operations.
Shutting off the Standing Pilot (temporary Shut off)
To shut off the standing pilot for service or summer shut down, press and hold the ON button on the Com-
mand Center for 3 seconds when the master switch is in the ON position (“-”) and the main burner is off.
Note
: Pilot will resume the next time system is turned on.
Key Combinations for System Settings
Note:
When On/Off wall switch is used, it must be in the On position to perform all system setups.
Function
operation
Default Setting
Intermittent/Standing
Hold the ON
▲
button while turning on the master switch
Intermittent
Pilot Setup
(Beep once for standing pilot, twice for intermittent pilot)
Pilot
Standing Pilot Temp.
Hold the ON
▲
button 3 seconds (when the master switch
Shutoff
on the main burner is off)
RF Remote Receiver
Push the RF receiver On/Off button on the control board
RF OFF
On/Off
Beep once for ON and beep twice for OFF
Learn Remote
Hold the OFF
▼
button while turning on the master switch
Transmitter
(Beep twice then press any handheld remote button)
6-hour safety
Press the ON
▲
button and OFF
▼
button simultaneously
ON
shutdown setup
(Beep once for ON, twice for OFF)