BDV7 Series Direct Vent Gas Fireplace
28
20301836
oPtIoNAl FAN / BloWeR SySteM
oPtIoNAl FAN/BloWeR SySteMS (Blot)
Installation Instructions
Wiring
1. Before installing the blower, wire the receptacle into an electrical circuit. This should be done be-
fore framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.
2. Remove the external junction box cover by removing the screw from the left side of the outside
firebox wall. Junction box was installed at the factory.
3. The junction box cover has a factory installed “romex” style strain relief connector. After connect-
ing the wires, route the wire leads through this connector. Refer to the wiring diagram in
Figure
45
.
BLACK
BLACK
WHITE
GREEN
BLACK
BLACK
BLACK
Receptacle
Junction
Box
120VAC
Optional Thermostatic Switch
Speed Control
FP2101
BDV blower wiring
Receptacle
Junction
Box
120VAC
Optional Thermostatic Switch
Speed Control
Figure 45 -
Blower Wiring Diagram