BDV7 Series Direct Vent Gas Fireplace
14
20301836
hoW to uSe the VeNt GRAPh
The Vent Graph should be read in conjunction with the
following vent installation instructions to determine the re-
lationship between the vertical and horizontal dimensions
of the vent system.
1. Determine the height of the center of the horizontal
vent pipe exiting through the outer wall. Using this di-
mension on the Sidewall Vent Graph,
Figure 14
, locate
the point intersecting with the slanted graph line.
2. From the point of this intersection, draw a vertical line
to the bottom of the graph.
3. Select the indicated dimension, and position the fire-
place in accordance with same.
exAMPle A:
If the vertical dimension from the floor of the unit is 11’ (3.4
m) the horizontal run to the face of the outer wall must not
exceed 14’ (4.3 m).
exAMPle B:
If the vertical dimension from the floor of the unit is 7’ (2.1
m), the horizontal run to the face of the outer wall must not
exceed 8
Z\x
’ (2.6 m).
Refer to
Page 21
for requirements for snorkels.
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
2 4 6 8 10 12 14 16 18 20
eg: A
FP2291
vent graph
20”
V
ertical Dimension from the Floor of Unit to the Center of
the Horizontal V
ent Pipe
Horizontal Dimension From the Outside of Termination to
the Back of the Fireplace
Figure 14 -
Side Wall Venting Graph
VeNtING INFoRMAtIoN
t-loCK PIPeS
When using unitized T-Lock pipe it is not necessary to
use sealant on the joints. The only areas of the venting
system that need to be sealed with high temperature sili-
cone sealant are the sliding joints of any telescope vent
sections used in the system.
To join T-Lock pipes together, simply align both inner and
outer pipes with the next section. Align the internal beads
of the female end with the T-channels of the male end.
Figure 13
Insert male end until beads on the female end contact
bottom of T-channel on male end. Twist pipe until beads
stop at ends of T-channel.
IMPoRtANt: Pipe can be twisted in either direction.
however, All PIPe SeCtIoNS MuSt Be RotAteD IN
the SAMe DIReCtIoN.
Securing the joints
with
sheet
metal
screws is not re-
quired.
To disassemble T-
Lock pipe, rotate pipe
sections until internal
beads on female end
align with diamond
indentations on male
end.
Figure 13a.
Pipe
sections will then eas-
ily separate by pulling
straight apart.
FP2741
T-lock undo
Arrow
Indentations
on Male End
Female End
FP2741
Figure 13a -
T-Lock Disassemble
FP2740
T lock channels
Internal
Beads
T-Channel
Female End
Male End
FP2740
Figure 13 -
T-Lock Pipe Joints
Arrow
Indentations