3.
You’ll see the Host Option menu and the first online
parameter.
Select Baud Rate:
2400
Press
d
or
u
until you see the baud rate you need, then
press
e
. You’ll see
Enter Parity: N
N)one, O)dd or E)ven
4.
Select the parity you need and press
e
. You’ll see
Enter Word Length [7-8]: 8
5.
Select the word length you need and press
e
. You’ll see
Enter Stop Bits [1-2]: 1
6.
Select the stop bits you need and press
e
. You’ll see
Enter Start (XON) character:
17
7.
Enter a number from 1-127 for XON flow control, or 128 for
DTR flow control. You’ll see
Enter Stop (XOFF) character:
19
8.
Enter a number from 1-127 for XOFF flow control, or 128 for
DTR flow control.
2-4 Communication Requirements