One to four digits to define the width of the supply in tenths of
millimeters (across the printhead).
Values:
191-1078
(0.75 to 4.25 inches)
;FORMAT_NAME
One to eight-character name assigned by the user. It can
contain any ASCII alphanumeric character, including slash (/),
hyphen (-), space ( ), dollar sign ($), or decimal point (.).
The Format Name is a character string, so it is preceded by a
semicolon (;).
Example
{F23, 500, 200;TEXTILES
p
The format number is
F23
, the supply length is
50
millimeters, the
supply width is
20
millimeters, and the format is named
"
TEXTILES
."
Te x t F i e l d R e c o r d
The text field record is constructed as shown below:
Syntax
T##,IFLAG,IVALUE,ROW,COL,MAG,TFONT,C-ROT,
F-ROT,COLOR
p
Field
Contents
T##
Must begin with the letter ‘T’ for a text field.
The T is followed by one or two digits for the field number.
There can be up to 100 fields per format, in any combination
of text, barcode, line, or graphic fields.
Values:
0-99
IFL AG
You can set numeric fields to increase or decrease in value as
each ticket is printed.
This parameter consists of one character to define the field as
incremented, decremented, or constant.
Values:
I
= Increment
D
= Decrement
Message Structures 3-9