19
8.4 Battery Disposal
Prior to disposing of the Phaser-Strobe pbx, the user must remove the
Nickel-Metal Hydride batteries. To do this, remove the lens, reflector
and lamp as detailed in the Lamp Replacement section. This will
expose four (4) screws that must be removed so the reflector housing
can be dismantled. There are four (4) additional screws in the case
half opposite the input and output jacks that must be removed. The
case halves can now be separated, exposing the batteries. Unplug
the batteries from the circuit board. The batteries should be sent to a
recycling center or returned to the factory. The rest of the parts may
now be disposed of.
9.0 SPECIFICATIONS*
Flash Range
30 - 50,000 FPM (Flashes Per Minute)
Flash Rate Accuracy
±0.004% of setting or ± least significant digit
Flash Rate Resolution
0.01 to 1 FPM (menu selectable),
0.1 FPM max resolution above 9,999.99 FPM
Display Update Rate
0.5 second typical above 120 RPM
External Modes
Flash Range and Display
Same as Internal Mode - external flash rates to 0
are acceptable
Tachometer Mode
5 to 250,000 RPM from external trigger
Accuracy: ±0.001% of reading or ± last digit
Display Update Rate
0.5 second typical
Trigger-to-Flash Delay
< 5 μsec
Phase Delay
Phase:
0.1 to 359.9°
Time:
0.01 to 1000 milliseconds
Auto:
0 to 200 VRPM
Internal Mode
Phaser-Strobe pbx