Measuring ranges
Function
Range
Resolution
Accuracy
DC voltage
(V
DC
)
200 mV
0.1 mV
±(0.5 % + 2 digits)
2000 mV
1 mV
20 V
0.01 V
200 V
0.1 V
±(0.8 % + 2 digits)
600 V
1 V
AC voltage
(V
AC
)
200 V
0,1 V
±(1.2 % + 10 digits)
50/60 Hz
600 V
1 V
DC current
(A
DC
)
2000
µ
A
1
µ
A
±(1.0 % + 2 digits)
20 mA
10
µ
A
200 mA
100
µ
A
±(1.2 % + 2 digits)
10 A
10 mA
±(2.0 % + 2 digits)
Resistance
(Ω)
200 Ω
0.1 Ω
±(0.8 % + 2 digits)
2000 Ω
1 Ω
20 kΩ
0.01 kΩ
200 kΩ
0.1 kΩ
2000 kΩ
1 kΩ
±(1.0 % + 2 digits)
Battery test
9 V
10 mV
±(1.0 % + 2 digits)
1.5 V
1 mV
Subject to technical modification.