![molex Brad HarshIO 600 User Manual Download Page 64](http://html.mh-extra.com/html/molex/brad-harshio-600/brad-harshio-600_user-manual_1824127064.webp)
HarshIO 600
•
64
•
IP67 MDR for EtherNET/IP
Ethernet Link (0xF6)
Class Attributes
Id
Description
Get
Set
Limits
1
Revision
⚫
4
2
Max Instance
⚫
3
3
Number of Instance
⚫
3
⚫
Supported
Not supported
Class Services
Id
Service
Param. Options
01h
Get_Attributes_All
0Eh
Get_Attribute_Single
Instance Attributes
Id
Description
Get
Set
Values
Instance 1
(ETH 1)
Instance 2
(ETH 2)
Instance 3
Internal Port
01
Interface Speed
⚫
Current Speed
100
02
Interface Flags
⚫
Link Status:
shall be set is a link is present on module
Half/Full Duplex:
shall reflect the duplex of the port
Negotiation Status:
-
If no Link :
Auto-negotiation not attempted
(in this case Link Status and Half/Full
Duplex
forced to “not set”)
-
If Link and attr6
not
in Auto-negotiate:
Auto-
negotiation not attempted
-
Other case:
Current auto-negotiation result
-
Link Status set
-
Half/Full Duplex set
-
Auto-negotiation no
attempted set
03
Physical Address
⚫
Mac address (All line below shall be consistent):
-
Displayed on the back label and on side label.
-
use by the module on Ethernet
04
Interface Counters
⚫
-
05
Media Counters
⚫
-
06
Interface Control
⚫
⚫
Current configuration
07
Interface Type
Twisted-Pair
The I/F is internal to the device
08
Interface State
The interface is enabled
09
Admin State
⚫
Enable the interface
10
Interface Label
⚫
ETH1
ETH2
Internal Port
11
Capabilities
⚫
100, Half (0) / 100, Full (1)
100, Full (1)
⚫
Supported
Not supported
Instance Services
Id
Service
Param. Options
01h
Get_Attributes_All
0Eh
Get_Attribute_Single
10h
Set_Attribute_Single
4Ch
Get_and_Clear