HarshIO 600
•
36
•
IP67 MDR for EtherNET/IP
5.
I/O Data mapping
I/O Messaging
HarshIO module supports up to a maximum of 8 I/O connections. Fewer connections allow faster data
I/O update rates (RPI value).
I/O Connections:
HarshIO module supports 2 transport Class 1 I/O connections (Cyclic and Change-Of-State triggers):
- 1x Exclusive Owner
- Unicast or Multicast (T=>O) connection
- Unicast (O=>T) connection o 7x Listen Only or Input Only (8 Input Only connection if no Exclusive
Owner connection)
- Multicast or Unicast (T=>O) connection
Note!
Listen Only connection allows a second Ethernet/IP scanner connected to the network
to listen the Input process data. For example, this feature is useful to share easily Inputs
with a HMI/Scada application.