background image

Operation - Using the Holding Cabinet 

 

 
 

 
 
 
 

Press             key to turn control ON. 

 
 
 
 

 

Pre-Heating w ill occur automatically. 

Pre-Heating stage will complete when both the pre-heat 

temperature and humidity settings are reached. 

 

NOTE: 

Pre-Heating only occurs on initial Start-Up.

 

 

 

When pre-heating is complete the Humidified Holding 
Cabinet is ready to use.  Refer to Item 4. Select Shelf
overleaf. 

 
 
 

 
 

 
 
 
 
 

Press                         to start using Humidified  
Holding Cabinet. 

 

 Press to turn OFF controller. 

Press        , display will return to the ‘Start’ 
screen shown below. 

Illuminates when Humidified  

Holding Cabinet is heating. 

Displays Set Temperature of Cabinet. 

 

 

Displays Actual Temperature of Cabinet. 

Press to turn Lights ‘On or Off’. 

Cooldown Mode. 

Summary of Contents for turbofan EH Series

Page 1: ...245286 1 Installation and Operation Manual EHT10 Humidified Holding Cabinet HEH...

Page 2: ...pares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1...

Page 3: ...old Time Expired Time s Up 10 Cabinet Settings Options End of Shift Cabinet Cool Down Manager Mode Parameters and Settings Flow Chart Selecting Manager Mode 1 Control ON 2 Enter Passcode 3 Manager Scr...

Page 4: ...ler Date Day Settings Controller Language Selection Not Used for this Application Temperature Units F C Setting Manager Mode Parameters and Settings Reference Table Holding Cabinet General Troubleshoo...

Page 5: ...answer your question Should you contact your TURBOFAN dealer on any matter concerning this Humidified Holding Cabinet please have the information provided opposite readily available This manual must b...

Page 6: ...20 240V 50HZ Single Phase L1 N E 2 25kW 9 4A 10 x 1 1 GN 20 x 12 Steam Pan Capacity 10 x Half Size Sheet Pan Capacity 27 8 74mm Water Connection USA Canada GHT All Other Markets BSP Water Supply Conne...

Page 7: ...eficiencies to the distributor who supplied the appliance 5 Ensure that all the castors are fitted securely 6 Check that the available electrical supply is correct to as shown on the Technical Data Pl...

Page 8: ...t side panel The EHT10 Humidified Holding Cabinet is supplied with factory fit ted power cord and plug 1 Correctly locate the Humidified Holding Cabinet into its final operating position and lock the...

Page 9: ...nitial Start Up When pre heating is complete the Humidified Holding Cabinet is ready to use Refer to Item 4 Select Shelf overleaf Press to start using Humidified Holding Cabinet Press to turn OFF cont...

Page 10: ...ting option required on this screen The display will show the shelf selected and the product selected The colour of the loaded shelf will be the same as the frame around the produced image selected NO...

Page 11: ...e product of the same kind this should be cooked and ready for loading onto the shelves Tick Button Closes the LAST SHELF screen and alarm Acknowledg es that the appropriate actions have been taken Th...

Page 12: ...product will display as either on the right side of the shelf or left side depending on which 1 2 Shelf option was selected 1 2 Shelf Load Right or 1 2 Shelf Load Left The colour of the loaded shelf w...

Page 13: ...ning the following Cool Down screen will display The display will show the current cabinet temperature Open the Cabinet door and allow the Cabinet to cool down When the cabinet temperature reaches the...

Page 14: ...Manager Mode Holding Cabinet Settings Programming 12 Manual...

Page 15: ...RAMMING Press to select the recipe to program The following screen will appear The Screen will appear as shown Select the recipe to edit Or Press to create new recipe or Press to delete a recipe The E...

Page 16: ...lect key The Screen will appear Select and the keypad will be displayed Enter the Hold Time required Hold Time Range 0 8 Hrs Press to confirm Press to cancel SELECT LAST SHELF TIME In the screen selec...

Page 17: ...Press to confirm changes Press to cancel changes SETTING WATER TANK HUMIDITY TEMPERATURE On the Hold Settings screen select to set the water tank temperature Enter the Water Tank temperature on the ke...

Page 18: ...m a USB IF NO USB HAS BEEN CONNECTED THE FOLLOWING ON SCREEN WARNING WILL APPEAR PLUG IN A USB DRIVE AND FOLLOW THE ON SCREEN PROMPTS On completion Press to cancel changes Screen will revert to Manage...

Page 19: ...will be available to manually set remaining time for product Press to Enable Disable manual shelf option HALF SHELF ENABLED DISABLED Allows the option of loading smaller trays of product to half the...

Page 20: ...Select Copy Images from USB the following warning will appear Follow the On Screen prompts Select Delete Recipe Images the following screen will appear Select Images to Delete These can be deleted in...

Page 21: ...nfirm setting Autostart Temp Range 60 90 C 140 194 F Press to confirm Press to cancel Press to set Autostart humidity Enter humidity level on keypad and confirm setting Autostart Humidity Range 10 85...

Page 22: ...cel DATE ENTRY SCREEN To change the Day press the number numeric key pad will display To change the Month press the number numeric key pad will display To change the Year press the number numeric key...

Page 23: ...temperature for cabinet 65 90 C 140 194 F 80 C 176 F WATER TANK HOLD TEMPERATURE Allows setting of temperature for water tank 10 85 C 50 185 F 70 C 158 F COPY HOLD TIMERS TO USB Pre programmed hold t...

Page 24: ...or all deleted Manager Screen 5 CHANGE PASSCODE Manager passcode can be changed 0000 9999 4500 AUTO START OPTIONS Autostart Autostart temperature can be pre set in real time Temperature Autostart hum...

Page 25: ...update installation not completed correctly corrupted on load A Call for service Touch Controller replacement required No beeper sound output from controller A Beeper sound volumes set to OFF in Mana...

Page 26: ...perature probe fault Open circuit A Probe fault B Probe connection circuit fault A Call for service B Call for service ERROR 8 Water Tank High Temperature Error Call For Service Water tank temperature...

Page 27: ...Electrical Schematic 25 1600W 240V 1600W 208V...

Page 28: ...W 4000K 241131 DOOR HINGE KIT EHT10 HP10T 237741 DOOR MAGNET 241045 DOOR SEAL 010723 CONDENSATE DRAWER 241149 DOOR CONDENSATE CHANNEL 242003 CASTOR SPACER 238391 CASTOR 65mm SWIVEL PU D BRAKE 238390 C...

Page 29: ...See adjacent Update by Service Menu Method Steps 1 2 to check if the Service Mode option is available The controller software can be installed by USB through the Service Mode if the existing software...

Page 30: ...h the Software Update Notification Instructions This SYSTEM screen can also be used to checked the version of Software operating if required The RECIPE SET shows the Recipe Menu Set installed on the C...

Page 31: ...e cabinet door and swap these over CABINET BODY 1 Remove four blanking screws covering alternate hinge holes on RH side of cabinet Refit cover screws on opposite side 2 Remove Top Hinge Bracket and Pa...

Page 32: ...ntally and vertically There should be a nominal gap of 6mm from edge of door to side of control panel 1 To align slacken off the upper and lower hinge plates and correctly align the door 2 Re tighten...

Page 33: ......