![Moffat turbofan EH Series Installation And Operation Manual Download Page 11](http://html1.mh-extra.com/html/moffat/turbofan-eh-series/turbofan-eh-series_installation-and-operation-manual_1823053011.webp)
Operation - Using the Holding Cabinet
9
When a product falls below a pre-set time (refer to
‘Manager Mode’ - ‘Hold Programming - ‘LAST SHELF’
time settings), while the number of remaining shelves of
that product is lower than the set number, the ‘LAST
SHELF’ pop-up screen will display with the product
Snooze Button
Snoozes the ‘LAST SHELF’ alarm for 5 minutes, the dis-
play will revert to the ‘LAST SHELF’ screen.
The screen will alternate between product description
loaded onto that shelf, showing time remaining and the
‘LAST SHELF’ screen.
This informs the operator that, should they require,
more product of the same kind, this should be cooked
and ready for loading onto the shelves.
Tick Button
Closes the ‘LAST SHELF’ screen and alarm. Acknowledg-
es that the appropriate actions have been taken.
The shelf with ‘LAST SHELF’ product will continue to
display.
Press the shelf / timer to cancel a Hold Timer when all
the product on that shelf has been used. The display will
return to the empty shelf display.
The following Cancel Shelf screens will display for Full
and Half Tray shelves.
Press to confirm.
Press to cancel.
On completion of the hold period for each shelf selected,
an alarm will sound.
The display title will show, ‘TIME’S UP’ , and the shelf
with expired holding time will display red
with .
Press the shelf showing ‘Red’ to cancel the alarm.
Press to return to previous screen.