![Moffat BLUE EVOLUTION G91 Service Manual Download Page 9](http://html1.mh-extra.com/html/moffat/blue-evolution-g91/blue-evolution-g91_service-manual_1822820009.webp)
2
Installation
7
Blue Seal Evolution Series Gas Salamander
© Copyright Moffat Ltd. 9 February 2016
Amendment 9
Clearances
NOTE:
Only non-combustible materials can be used in close proximity to this appliance.
*
We recommend allowing a clearance of 100mm on either side of appliance to allow access to side panels for servicing
purposes.
**
Using wall mounting accessories provided with this appliance.
***
Top clearances can be reduced where local fire protection system is provided, if allowed by local regulations.
Combustible Surface
Non-Combustible Surface
Left / Right Hand side
100mm
25mm (*)
Rear 50mm
30mm
(**)
Top Clearance to:
- Extraction Hood
200mm
- Grease Arresting Filter (***)
400mm
- Ceiling (***)
750mm
Australia / New Zealand