![Moffat BLUE EVOLUTION G91 Service Manual Download Page 43](http://html1.mh-extra.com/html/moffat/blue-evolution-g91/blue-evolution-g91_service-manual_1822820043.webp)
B
Appendix B: Gas Conversion
41
Blue Seal Evolution Series Gas Salamander
© Copyright Moffat Ltd. 9 February 2016
Amendment 9
Gas Specifications (From Ser No.401965)
- Australia:
- New Zealand:
- UK Only:
NOTE: * Measure burner operating pressure at manifold test point with both burners operating at full setting. Operating
pressure is ex-factory set and not to be adjusted, apart from when converting between gases, if required. (Refer to
‘Gas Conversion’ section for details).
Natural Gas (G20)
Propane (G31)
Main Burner Injectors
Ø 1.85mm
Ø 1.15mm
Low Fire:
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½
turn out (c.c.w.)
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
10 mbar (*)
26 mbar
Gas Regulator Cap Screw
Natural Gas
LP Gas (Propane)
Main Burner Injectors
Ø 1.85mm
Ø 1.15mm
Low
Fire
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½ turn out (c.c.w.)
Supply Pressure
1.13 - 3.4 kPa
2.75 - 4.5 kPa
Burner Operating Pressure (*)
1.0 kPa
2.55 kPa
Gas Regulator Cap Screw
Natural Gas
LP Gas
Main Burner Injectors
Ø 1.85mm
Ø 1.15mm
Low Fire
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (c.c.w.)
½ turn out (c.c.w.)
Supply Pressure
1.13 - 3.4 kPa
2.75 - 4.5 kPa
Burner Operating Pressure (*)
1.0 kPa
2.55 kPa
Gas Regulator Cap Screw