![Moffat BLUE EVOLUTION G91 Service Manual Download Page 44](http://html1.mh-extra.com/html/moffat/blue-evolution-g91/blue-evolution-g91_service-manual_1822820044.webp)
B
Appendix B: Gas Conversion
42
Blue Seal Evolution Series Gas Salamander
© Copyright Moffat Ltd. 9 February 2016
Amendment 9
- All Other Countries:
(*) NOTE:
(*) Measure burner operating pressure at manifold test point with both burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from when
converting between gasses, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications’ section of this manual for further details.
Natural Gas
Town Gas (**)
Main Burner Injectors
Ø 1.85mm
Ø 3.50mm
Low Fire:
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (ccw)
4 turns out (ccw)
Supply Pressure
1.13 - 3.40 kPa
0.76 - 1.50 kPa
Burner Operating Pressure (*)
1.00 kPa
0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure)
LP Gas (Propane)
Butane
Main Burner Injectors
Ø 1.15mm
Ø 1.10mm
Low Fire:
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
½ turn out (ccw)
½ turn out (ccw)
Supply Pressure
2.75 - 4.50 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.55 kPa
2.55 kPa
Gas Regulator Cap Screw