8 Technical data
8.4 General
XP-503 01/2017 MN048014 EN www.eaton.com
69
Supply voltage
24 V DC
1)
18..36 V DC (SELV)
The applied voltage must meet the requirements for safety extra-low voltages (SELV)
set forth in IEC 60950 and – in connection with the UL listing – the requirements for a
low-voltage source set forth in UL 508!
Power consumption
XP-503-10
max. 1.2 A
XP-503-15
max. 1.5 A
XP-503-21
max. 1.7 A
Mechanical dimensions
Depends on the specific device version
Weight
XP-503-10
2.70 kg
XP-503-15
4.95 kg
XP-503-21
7.55 kg
Ambient air temperature
Operation
(vertical ±10° mounting position)
0 ºC to +50 ºC
[system with CFast, SSD, mSATA memory]
(with natural convection)
+5 ºC to +50 ºC
[system with HDD]
(with natural convection)
Storage
-20 ºC to +60 ºC
Relative humidity
10% … 90%, non-condensing
Ambient air
Free of corrosive gases
Burn-in test
24 h burn-in [system without HDD]
48 h burn-in [system with HDD]
Tab. 15
Technical data