STEPPING METHOD 3
– RAKE/CUT YOUR BOTTOM PANEL TO THE SLOPE USING 2100MM WORTH OF
WALL PANELS TO MAINTAIN A MINIMUM 1800MM WALL HEIGHT.
You will maintain a maximum height of 1800mm wall height – As pictured below it should be noted that your
wall height at the high side of the slope will be increased by the amount of the rake – in this situation 100mm.
Depending on the additional height gained by doing this you may require deeper footings and longer posts.
Please contact us for specific advice before installation.
1800-1900mm High wall shown
Insert post infill here
Insert post infill here
Cut panel to suit the slope of the ground
Support bracket height
= Normal placement for
a 1800mm wall + the
amount of the rake on
both sides of post
Example of a 100mm fall over
this distance
Cutting of a panel to suit a 100mm rake / slope
N.B On a larger rake / slope a longer basel channel may be required
1000
1200
Cut
900
1900
1900
1000
1800
100
ADDITIONAL
STEPPING OR RAKING YOUR WALL