background image

5

 

 

 

Never connect components under load.  

 

Do not mount or support these 

xtures in a manner that can cut the outer jacket or damage wire 

insula

ti

on.  

 

Unless individual product speci

ca

ti

ons deem otherwise:  Never connect an LED product directly to a 

dimmer packs, occupancy sensors, 

ti

ming devices, or other related control devices.  LED 

xtures must be 

powered directly o

 a switched circuit.  

 

Unless individual product speci

ca

ti

ons deem otherwise:  Do not restrict 

xture ven

til

a

ti

on.  Allow for 

some volume of airspace around 

xture.  Avoid covering LED 

xtures with insula

ti

on, foam, or other 

material that will prevent convec

ti

on or conduc

ti

on cooling.  

 

Unless individual product speci

ca

ti

ons deem otherwise: Do not exceed 

xtures maximum ambient 

temperature.   

 

Only use 

xture in its intended loca

ti

on.     

 

LED products are Polarity Sensi

ti

ve.  Ensure proper Polarity before installa

ti

on.   

 

Electrosta

ti

c Discharge (ESD): ESD can damage LED 

xtures.  Personal grounding equipment must be 

worn during all installa

ti

on or servicing of the unit.  

 

Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter 
performance.  

 

Some components inside the 

xture may not be serviceable.  In the unlikely event your unit may require 

service, stop using the unit immediately and contact an ABL representa

ti

ve for assistance. 

 

Always read the 

xtures complete installa

ti

on instruc

ti

ons prior to installa

ti

on for any addi

ti

onal 

xture 

spec

ifi

c warnings.     

 

CAUTION:  RISK OF PRODUCT DAMAGE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect or turn o

 power before 

installa

ti

on or servicing. 

 

Verify that supply voltage is correct by 
comparing it with the luminaire label 
informa

ti

on. 

 

Make all electrical and grounded 
connec

ti

ons in accordance with the Na

ti

onal 

Electrical Code (NEC) and any applicable 
local code requirements. 

 

All wiring connec

ti

ons should be capped 

with UL approved recognized wire 
connectors. 

 

WARNING 

RISK OF ELECTRIC SHOCK 

 

 

Allow lamp/

xture to cool before handling. 

Do not touch enclosure or light source. 

 

Do not exceed maximum wa

tt

age marked on 

luminaire label.  

 

Follow all manufacturer’s warnings, 
recommenda

ti

ons and restric

ti

ons for: driver 

type, burning posi

ti

on, moun

ti

ng 

loca

ti

ons/methods, replacement and 

recycling.    
 

 
 
 

 

WARNING 

RISK OF BURN 

 

 

Wear gloves and safety glasses at all 

ti

mes 

when removing luminaire from carton, 
installing, servicing or performing 
maintenance. 

 

Avoid direct eye exposure to the light source 
while it is on. 
 

CAUTION 

RISK OF INJURY 

 

 

Keep combus

ti

ble and other materials that 

can burn, away from lamp/lens.   

 

Do not operate in close proximity to persons, 
combus

ti

ble materials or substances 

aff

ected by heat or drying.  

 

 

CAUTION 

RISK OF FIRE 

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties.

Summary of Contents for Clarity LED

Page 1: ...CLARITY LED INSTALLATION MANUAL ...

Page 2: ...et in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes this matter should be referred to Modular Services Company Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the luminair...

Page 3: ...tion or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes this matter should be referred to Modular Services Company Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the product information Make all electrical and grou...

Page 4: ...ng or performing routine maintenance upon this equipment follow these general precautions Installation and service of luminaires should be performed by a qualified licensed electrician Maintenance of the luminaires should be performed by person s familiar with the luminaires construction and operation and any hazards involved Regular fixture maintenance programs are recommended It will occasionall...

Page 5: ...istance Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings CAUTION RISK OF PRODUCT DAMAGE Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the luminaire label information Make all electrical and grounded connections in accordance with the National Electric...

Page 6: ...y 4 Review final approved shop drawings and submittal booklet The following documents will provide you with technical details specific to the installation Wiring Diagrams that are on a decal and placed on the fixture The Installation Manual for that specific fixture UNIT INSTALLATION This product must be installed in accordance with the applicable installation code by a person familiar with the co...

Page 7: ... Fixtures Clarity 3ft Fixtures Clarity 4ft Fixtures Clarity 3ft Fixtures 3 At least two 2 stabilizing fasteners should be located in Area H above the backplate hook to keep the mounting plate from pivoting forward Fig 2 The location of the vertical wall studs are to be determined by the installation contractor The hole in area H must be countersunk and the fastener must be flat head The hardware i...

Page 8: ...ture on backplate engaging fixture hook over backplate hook 3 If the bed power interrupt switching bed stop option was ordered see Figure 3 for assembly of the provided spacers over the backplate studs If bed stop option is not provided omit the spacers shown in Figure 3 4 Secure the fixture with the washers and nuts provided 5 If bed stop option is provided test fixture for free vertical movement...

Page 9: ...and number of wires being used 4 If a low voltage controller was ordered refer to the wiring diagram on the controller label for the wiring options 5 Connect the grounding wire of fixture to a proper ground LENS INSTALLATION 1 Orient each lens as shown in Figure 4 Position 1 There is a groove at the front of the lens which runs the length of the lens Install the lens on the groove indicated in Fig...

Page 10: ...ackplate 4 Tighten Phillips screws to secure this setting 5 Test the bed stop s function for operation as per the testing procedure below Testing Functions 1 Test continuity from COM TERMINAL to NO TERMINAL 2 Proper function of the fixture will have continuity with the housing against backplate as shown in Figure 5 Detail B 3 As the housing is moved away from the backplate continuity should be los...

Page 11: ...or a period of 12 months from date of the owner s acceptance to the installing contractor or the date the equipment is put into service whichever comes first Warranty excludes electric lamps and or any material not furnished by Modular Services Warranty does not cover damage due to improper installation and or abuse It is the responsibility of the customer to report any noted product deficiencies ...

Reviews: