Electrosta

ti

c Discharge (ESD): ESD can damage product(s).  Personal grounding equipment must be 

worn during all installa

ti

on or servicing of the unit.  

 

Do not touch individual electrical components as this can cause ESD and 

aff

ect product performance.  

 

Do not stretch or use cable sets that are to short or are of insu

cient length.  

 

Do not tamper with contacts. 

 

Do not modify the product.  

 

Do not change or alter internal wiring or installa

ti

on circuitry.  

 

Do not use product for anything other than its intended use. 

 

If installing latching springs: ensure that the springs are fully engaged prior to moving to next 
connec

ti

on.  

 

If installing wiring systems: Materials and component parts of a manufacturing wiring system as 
described in Ar

ti

cle 604 of the Na

ti

onal Electric Code and Underwriters Laboratories Standard for 

Safety #183 

MUST BE

 installed.  

 

CAUTION:  RISK OF PRODUCT DAMAGE 

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties.

LED IMPORTANT SAFETY INSTRUCTIONS

• 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, 
and other hazards please read all warnings and instructions included with and on the fixture box and all fixture 
labels.

• 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general 
precautions.

• 

Installation and service of luminaires should be performed by a qualified licensed electrician.

• 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and 
operation and any hazards involved. Regular fixture maintenance programs are recommended.

• 

It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on 
ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a 
solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. 
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing 
damaged gaskets as necessary.

• 

DO NOT INSTALL DAMAGED PRODUCT! 

This luminaire has been properly packed so that no parts should have been 

damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be 
replaced.

• 

Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.

• 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible 
contingency to meet in connection with installation, operation, or maintenance. Should further information be 
desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s 
purposes, this matter should be referred to Modular Services Company.

Summary of Contents for Clarity LED

Page 1: ...CLARITY LED INSTALLATION MANUAL ...

Page 2: ...et in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes this matter should be referred to Modular Services Company Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the luminair...

Page 3: ...tion or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes this matter should be referred to Modular Services Company Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the product information Make all electrical and grou...

Page 4: ...ng or performing routine maintenance upon this equipment follow these general precautions Installation and service of luminaires should be performed by a qualified licensed electrician Maintenance of the luminaires should be performed by person s familiar with the luminaires construction and operation and any hazards involved Regular fixture maintenance programs are recommended It will occasionall...

Page 5: ...istance Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings CAUTION RISK OF PRODUCT DAMAGE Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the luminaire label information Make all electrical and grounded connections in accordance with the National Electric...

Page 6: ...y 4 Review final approved shop drawings and submittal booklet The following documents will provide you with technical details specific to the installation Wiring Diagrams that are on a decal and placed on the fixture The Installation Manual for that specific fixture UNIT INSTALLATION This product must be installed in accordance with the applicable installation code by a person familiar with the co...

Page 7: ... Fixtures Clarity 3ft Fixtures Clarity 4ft Fixtures Clarity 3ft Fixtures 3 At least two 2 stabilizing fasteners should be located in Area H above the backplate hook to keep the mounting plate from pivoting forward Fig 2 The location of the vertical wall studs are to be determined by the installation contractor The hole in area H must be countersunk and the fastener must be flat head The hardware i...

Page 8: ...ture on backplate engaging fixture hook over backplate hook 3 If the bed power interrupt switching bed stop option was ordered see Figure 3 for assembly of the provided spacers over the backplate studs If bed stop option is not provided omit the spacers shown in Figure 3 4 Secure the fixture with the washers and nuts provided 5 If bed stop option is provided test fixture for free vertical movement...

Page 9: ...and number of wires being used 4 If a low voltage controller was ordered refer to the wiring diagram on the controller label for the wiring options 5 Connect the grounding wire of fixture to a proper ground LENS INSTALLATION 1 Orient each lens as shown in Figure 4 Position 1 There is a groove at the front of the lens which runs the length of the lens Install the lens on the groove indicated in Fig...

Page 10: ...ackplate 4 Tighten Phillips screws to secure this setting 5 Test the bed stop s function for operation as per the testing procedure below Testing Functions 1 Test continuity from COM TERMINAL to NO TERMINAL 2 Proper function of the fixture will have continuity with the housing against backplate as shown in Figure 5 Detail B 3 As the housing is moved away from the backplate continuity should be los...

Page 11: ...or a period of 12 months from date of the owner s acceptance to the installing contractor or the date the equipment is put into service whichever comes first Warranty excludes electric lamps and or any material not furnished by Modular Services Warranty does not cover damage due to improper installation and or abuse It is the responsibility of the customer to report any noted product deficiencies ...

Reviews: