9
ELECTRICAL CONNECTIONS
NOTE:
Ensure that all power is disconnected at the breaker governing the circuit load. Only qualified electricians
should attempt installation of this product.
1. Disconnect the power to all of the circuits before wiring the fixture.
2. For fixtures with bed-stop option, connect 12 AWG stranded leads (by others) to the building wire in the
junction box, then connect them to the fixture leads inside fixture. Do not run solid wire into fixtures with
the bed-stop option. The fixture must be free to "float" on mounting plate and solid wires would restrain the
movement of the fixture.
3. Following the wiring diagram provided with the fixture, connect the fixture leads to the power supply leads
and connect any optional switching leads using connectors (by others) suitable for the gauge and number of
wires being used.
4. If a low voltage controller was ordered, refer to the wiring diagram on the controller label for the wiring
options.
5. Connect the grounding wire of fixture to a proper ground.
LENS INSTALLATION
1. Orient each lens as shown in Figure 4, Position 1. There is a groove at the front of the lens which runs the
length of the lens. Install the lens on the groove indicated in Figure 4, Detail views A and B.
2. Rotate the lens into position until the lens tab comes in contact with the fixture housing (Position 2).
3. Start on one end and carefully flex the lens so that the lens tab snaps into place on the housing (Position 3).
Continue this procedure along the length of the lens until it is completely retained.
4. To remove the lens, pull on the curled tab until the lens is pulled away from the housing (Position 4). Start at
one end and proceed along the lens.
NOTE:
Do not use tools such as screwdrivers to pry on the lens during installation or removal. Lens breakage may
occur.
Figure 4.