121
/140
Virtual PTZ And Full Image Recording
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
Activate/Deactivate Full Image Recording In The Browser
To configure this feature, open the
Setup Menu > Event Control > Recording
dialog and
activate or deactivate the
“Full Image Recording” option
.
Notes
Post-event search in the full image:
If you are using Full Image Recording on D25M
cameras, you should use at least MEGA resolution when storing. This will facilitate later
searches in
MxControlCenter
or
MxEasy
. The advanced distortion correction features
require this function to deliver satisfactory image quality.
Full Image Recording On:
Due to its increased computing power, full image record-
ing reduces the data rate of the live image stream, which may drop by about 10 to 30
percent. It is therefore recommended to reduce the image rate for storage as much as
possible, so as to affect the live image stream as little as possible.
Full Image Recording Off:
The event that triggered a video motion (VideoMotion VM)
window may not be in the recorded sequences as the window was not displayed at
the time.