AWS-4000
Technical Installation Guide
Mobileye Technologies Ltd.
Proprietary and Confidential
Page 45
3.3.9.
Signal Test & Configuration step
In this step you need to click on the "Start Test" button in order
for the application to check the signals polarity.
If one or more of the signals polarity is incorrect you will need
to choose the Correct Polarity, Click "Burn Now" and then
perform the Test again.
Only when all signals are labeled with a Green Check Icon
beside them, may you proceed to the next stage.
At this stage you can also choose to change the Signal Source
between MLD and CAN if needed.
NOTE
:
Please be aware that if a Signal Polarity is set too High, it will pass the test
even if the signal itself is not connected.
When testing Analog Signals Do Not Activate the signal switch after clicking the
"Start Test" Button.
When testing Digital Signals Activate the Signal Switch after clicking the "Start
Test" Button.
If the Signal Test has been successful (all signals polarities and
connections are correct), proceed to the Test Drive by clicking
‘Next’.